DELL PC7024 User Manual
System Management Commands
1627
Unit Description Status Source Average Current Since
Power Power Date/Time
(Watts) (Watts)
---- ----------- ----------- ------ ---------- ------- -----------------
1
System
OK AC 206710688 81540
1
Main
OK AC
44896
81540 01/10/2031 15:58:46
1 Secondary
Not
present
DC
show system temperature
Use the show system temperature command in User EXEC or Privileged
EXEC mode to display information about the system temperature and fan
status.
Syntax
show system temperature
Parameter Description
This command does not require a parameter description.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC, Privileged EXEC
User Guidelines
Temperature status is indicated as per the following table:
Status
Degrees Celsius
Good
0-50
Medium
51-74
High
75-200
2CSPC4.XCT-SWUM2XX1.book Page 1627 Monday, October 3, 2011 11:05 AM