Product Characteristics 
 
4.4 SCALANCE X206-1 
 
Notice 
The C-PLUG may only be inserted or removed when the power is off! 
 
Removing the C-PLUG 
It is only necessary to remove the C-PLUG if the basic device develops a fault. 
The C-PLUG can be removed from the slot using flat pliers, tweezers, or a small screwdriver. 
4.4.9 
SCALANCE X206-1 Displays 
Fault indicator (red LED) 
 
Status 
Meaning 
lit red 
The SCALANCE X206-1 detects an error. At the same time, the 
signaling contact opens.  
The following faults are detected: 
1.  Link down event on a monitored port 
2.  Failure of one of the two redundant power supplies. 
3.  Device startup, the LED is lit for approx. 20s. 
flashes red 
An internal fault was detected. 
Notify the maintenance personnel and, if necessary, send the 
device in for repair. 
not lit 
No fault detected by the SCALANCE X206-1. 
Power indicator (green LED) 
The status of the power supply is indicated by two green LEDs: 
 
Status 
Meaning 
lit green 
Power supply L1 or L2 is connected. 
not lit 
Power supply L1 and/or L2 not connected or <14 V. 
Port status indicator (green/yellow LEDs) 
The status of the ports is indicated by seven two-color LEDs: 
 
Status 
Meaning 
Port 1 through 8 LED lit green 
TP link exists, no data reception 
Port 1 through 8 LED lit yellow 
TP link exists, data received at TP port 
 