Cisco Systems SRW248G4P User Manual

Page of 72
Chapter 
Configuring the Switch
48-Port 10/100 + 4-Port Ggabt Swtch wth WebVew and Power over Ethernet
Statistics > RMON Alarms
The RMON Alarms screen allows you to record important 
events  and  critical  network  problems . The  RMON  Alarm 
and  Event  Control  Tables  are  used  together  to  define 
specific criteria that will generate response events .
Alarms  can  be  set  to  test  data  over  any  specified  time 
interval  and  can  monitor  absolute  or  changing  values, 
such as a statistical counter reaching a specific value, or a 
statistic changing by a certain amount over a set interval . 
Alarms  can  be  set  to  respond  to  either  rising  or  falling 
thresholds . 
Statistics > RMON Alarms
The  Alarm  Control Table  allows  you  to  add,  update  and 
delete specific index entries .
Interface 
The selected interface on the Switch .
Statstcs 
The traffic statistics to be sampled . Select from 
the drop-down list .
Interval 
The  time  interval  in  seconds  over  which  data 
is  sampled  and  compared  with  the  rising  or  falling 
threshold .
Sample  Type 
The  method  of  sampling  data,  either 
Absolute or Delta . For an absolute sample the variable will 
be compared directly to the thresholds . For a delta sample 
the last sample is subtracted from the current value and 
the difference is then compared to the thresholds .
Startup  Alarm 
How  the  alarm  is  activated  when  the 
variable is compared to the thresholds . This can be set to 
Rising, Falling, or Rising or Falling .
Rsng  Threshold 
An  alarm  threshold  for  the  sampled 
variable .  If  the  current  value  is  greater  than  or  equal  to 
the threshold, and the last sample value was less than the 
threshold, then an alarm will be generated . (After a rising 
event has been generated, another such event will not be 
generated  until  the  sampled  value  has  fallen  below  the 
Rising Threshold and reaches the Falling Threshold .)
Fallng  Threshold 
An  alarm  threshold  for  the  sampled 
variable .  If  the  current  value  is  less  than  or  equal  to  the 
threshold, and the last sample value was greater than the 
threshold, then an alarm will be generated . (After a falling 
event has been generated, another such event will not be 
generated  until  the  sampled  value  has  risen  above  the 
Falling Threshold and reaches the Rising Threshold .)
Rsng  Event  Index  (0-) 
The  index  of  the  Event 
that will be used if a rising alarm is triggered . If there is no 
corresponding entry in the Event Control Table, or if this 
number is zero, then no event will be generated .
Fallng  Event  Index  (0-) 
The  index  of  the  Event 
that will be used if a falling alarm is triggered . If there is no 
corresponding entry in the Event Control Table, or if this 
number is zero, then no event will be generated .
Owner 
The name of the person who created this entry in 
the Control Table . 
Statistics > RMON Events
An RMON Event determines the action to take when an 
alarm is triggered . The response to an alarm can include 
logging  the  alarm  or  sending  an  SNMP  trap  message .  If 
the response corresponding to an alarm has not yet been 
defined,  use  the  RMON  Event  screen  to  configure  the 
Event Setting table .
Statistics > RMON Events