Connecting the Switch
48-Port 10/100 + 4-Port Ggabt Swtch wth WebVew and Power over Ethernet
Chapter 
Chapter :  
Connectng the Swtch 
Overview
This chapter will explain how to connect network devices 
to  the  Switch .  The  following  diagram  shows  a  typical 
network configuration .
Internet
Cable ./DSL 
Modem
Router
Wireless 
Access Point
Desktop
Notebook
Server
Typical Network Configuration
When you connect your network devices, make sure you 
don’t exceed the maximum cabling distances, which are 
listed in the following table:
Maxmum Cablng Dstances
From
To
Maxmum Dstance
Switch
Switch or Hub
100 meters (328 feet)
Hub†
Hub
5 meters (16 .4 feet)
Switch or Hub†
Computer
100 meters (328 feet) 
A hub refers to any type of 100Mbps hub . A 10Mbps hub connected 
to another 10Mbps hub can span up to 100 meters (328 feet) .
Pre-Installation Considerations
Fast Ethernet Considerations
If  you  are  using  the  Switch  for  Fast  Ethernet  (100Mbps) 
applications, you must observe the following guidelines:
Full-Duplex Considerations
The  Switch  provides  full-duplex  support  for  its  RJ-45 
ports .  Full-duplex  operation  allows  data  to  be  sent  and 
received simultaneously, doubling a port’s potential data 
throughput . If you will be using the Switch in full-duplex 
mode, the maximum cable length using Category 5 cable 
is 328 feet (100 meters) .
1000BASE-T Cable Requirements
All  Category  5  UTP  cables  that  are  used  for  100Base-TX 
connections  should  also  work  for  1000Base-T,  providing 
that  all  four  wire  pairs  are  connected .  However,  it  is 
recommended  that  for  all  critical  connections,  or  any 
new cable installations, Category 5e (enhanced Category 
5)  or  Category  6  cable  should  be  used .  The  Category 
5e  specification  includes  test  parameters  that  are  only 
recommendations  for  Category  5 .  Therefore,  the  first 
step in preparing existing Category 5 cabling for running 
1000Base-T is a simple test of the cable installation to be 
sure that it complies with the IEEE 802 .3ab standards .
Positioning the Switch
Before you choose a location for the Switch, observe the 
following guidelines:
Make  sure  that  the  Switch  is  accessible  and  that  the 
cables can be connected easily .
Keep  cabling  away  from  sources  of  electrical  noise, 
power lines, and fluorescent lighting fixtures .
Position  the  Switch  away  from  water  and  moisture 
sources .
To  ensure  adequate  air  flow  around  the  Switch,  be 
sure  to  provide  a  minimum  clearance  of  two  inches 
(50mm) .
Do  not  stack  free-standing  Switches  more  than  four 
units high .
Placement Options
There are two ways to physically install the Switch, either 
set the Switch on its four rubber feet for desktop placement 
or mount the switch in a standard-sized, 19-inch high rack 
for rack-mount placement .