For systems running the Windows® 2000 operating system:
1
From the desktop, select Start - Settings - Control Panel - Mouse.
2
Click the Motion tab.
3
Set the Acceleration setting to None and the speed setting to the default of 50%
Connecting a SIP
To connect a SIP to each server:
1
Locate the SIPs for your 2161DS Console Switch unit.
2
Attach the SIP or AVRIQ ends to the appropriate keyboard, monitor, and mouse ports on the 
first server you will be connecting to this 2161DS Console Switch unit.
3
Attach one end of the CAT 5 cabling that will run from your SIP to the 2161DS Console 
Switch unit to the RJ45 connector on the SIP.
4
Connect the other end of the CAT 5 cable to the desired Analog Rack Interface (ARI) port on 
the back of your 2161DS Console Switch unit.
5
Repeat steps 2-4 for all servers you wish to attach.
 
NOTE: 
Power down the 2161DS Console Switch unit before servicing. Always disconnect the power 
cord from the wall outlet.Power down the 2161DS Console Switch unit before servicing. Always 
disconnect the power cord from the wall outlet.
 
NOTE: 
In addition to Dell SIPs, the 2161DS Console Switch may also be connected to servers using 
Avocent AVRIQ, including Sun and Serial AVRIQs.
Adding a PEM (Optional)
A Port Expansion Module (PEM) allows you to expand each ARI port to accommodate up to eight 
servers instead of one.
 
NOTE: 
The PEM operates passively. Therefore, once a user accesses a server attached to a PEM, any 
subsequent users attempting to access any of the servers attached to that PEM will be blocked.
To add a PEM (optional):
1
Mount the PEM into your rack. Using up to nine CAT 5 cables, one connects your 2161DS 
Console Switch unit to the PEM, and the other eight connect the PEM to the SIP attached to 
each server.
2
Attach one end of the CAT 5 cabling that will run between your PEM and the 2161DS 
Console Switch unit to the RJ45 connector slightly separate from the other connectors on the 
PEM. Connect the remaining end of the CAT 5 cable to the desired ARI port on the back of 
your 2161DS Console Switch unit.