Cabletron Systems 2M46 User Manual

Page of 120
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices
2-2
Local Management Supplement
The following introduces each screen that is accessible from the Repeater 
Configuration Menu screen.
REPEATER LEVEL SECURITY CONFIGURATION
Used to set the state of security of all ports on each connector, 
simultaneously. The ports can be set to receive all frames (NonSecure 
state), lock on the source address of the next frame received 
(LockOnNext), or lock on the address of the last frame received 
(LockedOnAddr). For details, refer to 
.
PORT LEVEL SECURITY CONFIGURATION
Used to set the security for each port of a connector, individually. For 
details, refer to 
2.2
REPEATER LEVEL SECURITY CONFIGURATION
The Repeater Level Security Configuration screen, 
, is used to 
set the state of security according to connector. All ports on a connector 
can be set to receive all frames (NonSecure state), lock on the source 
address of the next frame received (LockOnNext), or lock on the source 
address of the last frame received (LockedOnAddr). When either of the 
last two options are set, the switch can be set to enable or disable the 
reception of frames and send or not send traps when an intruder is 
detected.
To access the Repeater Level Security Configuration screen, use the arrow 
keys to highlight the REPEATER LEVEL SECURITY 
CONFIGURATION
 menu item on the Repeater Configuration Menu 
screen and press ENTER. The Repeater Level Security Configuration 
screen displays.