DELL N3000 User Manual

Page of 1460
100
Hardware Overview
Power Consumption for N2000 Series PoE Switches
Table 3-5 shows power consumption data for the PoE-enabled switches.
The PoE power budget for each interface is controlled by the switch firmware. 
The administrator can limit the power supplied on a port or prioritize power 
to some ports over others. Table 3-6 shows power budget data.
Stack 
master
Off
The switch is in stand-alone mode.
Solid green
The switch is master for the stack.
Temp
Solid green
The switch is operating below the threshold 
temperature.
Solid red
The switch temperature exceeds the threshold of 75°C.
Stack No. –
Switch ID within the stack.
Table 3-5. Power Consumption
Model
Input 
Voltage
Power Supply 
Configuration
Max Steady 
Current 
Consumption (A)
Max Steady 
Power (W)
N2024P
100V
Main PSU+EPS PSU
8.9
890.0
110V
Main PSU+EPS PSU
8.3
913.0
120V
Main PSU+EPS PSU
7.6
912.0
220V
Main PSU+EPS PSU
4.0
880.0
240V
Main PSU+EPS PSU
3.6
873.6
N2048P
100V
Main PSU+EPS PSU
17.8
1780.0
110V
Main PSU+EPS PSU
15.8
1740.2
120V
Main PSU+EPS PSU
14.5
1740.0
220V
Main PSU+EPS PSU
7.7
1687.4
240V
Main PSU+EPS PSU
7.1
1704.0
Table 3-4. System LED Definitions (Continued)
LED
Color Definition