Managing a Switch Stack
Upgrading the firmware on a stack of switches is the same as upgrading the 
firmware on a single switch. After you download a new image by using the File 
Download page or copy command, the downloaded image is distributed to all 
the connected units of the stack. For more information about downloading 
What is Stacking Standby?
A standby unit is preconfigured in the stack. If the current stack master fails, 
the standby unit becomes the stack master. If no switch is pre-configured as 
the standby unit, the software automatically selects a standby unit from the 
existing stack units.
When the failed master resumes normal operation, it joins the stack as a 
member (not a master) if the new stack master has already been elected.
The stack master copies its running configuration to the standby unit 
whenever it changes (subject to some restrictions to reduce overhead). This 
enables the standby unit to take over the stack operation with minimal 
interruption if the stack master becomes unavailable.
Operational state synchronization also occurs:
• when you save the running configuration to the startup configuration on 
the stack master.
• when the backup unit changes.
What is Nonstop Forwarding?
Networking devices, such as the Dell Networking series switches, are often 
described in terms of three semi-independent functions called the forwarding 
plane, the control plane, and the management plane. The forwarding plane 
forwards data packets and is implemented in hardware. The control plane is 
the set of protocols that determine how the forwarding plane should forward 
packets, deciding which data packets are allowed to be forwarded and where 
they should go. Application software on the stack master acts as the control 
plane. The management plane is application software running on the stack 
master that provides interfaces allowing a network administrator to configure 
the device. 
The Nonstop Forwarding (NSF) feature allows the forwarding plane of stack 
units to continue to forward packets while the control and management 
planes restart as a result of a power failure, hardware failure, or software fault