DELL N3000 User Manual
196
Managing a Switch Stack
When all four units are up and running, the show switch CLI command gives
the following output:
console#show switch
At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW
Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
---
---------
-------
--------
--------- ------- --------
1
Stack Member
N3048
N3048
OK
6.0.0.0
2
Stack Member
N3048
N3048
OK
6.0.0.0
3
Mgmt Switch
N3048
N3048
OK
6.0.0.0
4
Stack Member
N3048
N3048
OK
6.0.0.0
SW
Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- ---------
-------
--------
-------------------
--------
1
Stack Member
N3048
N3048
OK
6.0.0.0
2
Unassigned
N3048
Not Present 0.0.0.0
3
Mgmt Switch
N3048
N3048
OK
6.0.0.0
4
Stack Member
N3048
N3048
OK
6.0.0.0