Cabletron Systems SmartCell 6A000 User Manual

Page of 102
SmartCell 6A000 User Guide   3-5
     
   
6.
Configure the ATM interface or adapter for all end nodes and edge devices. Typically, configuration 
consists of specifying LAN Emulation as the protocol, assigning the device an IP address that 
corresponds to the subnet of the switch's client, and indicating that you want the device to use the 
Well Known LECS Address or the ILMI acquired LECS address as the address for the LECS.
7.
Messages are displayed on the console as each end device registers with the LES and BUS. You can 
check connectivity by pinging between end nodes.
Your ELAN is now operational. Additional ELANs can be created in the same way. See Chapter 4, "Switch 
Administration." for information about SmartCell 6A000 switch operations and maintenance.
Note
While it is possible for a single ELAN on the SmartCell 6A000 switch to support 
multiple subnets, in general, switch performance is best and management easiest 
when the "One-subnet-per-ELAN" rule is observed.
3.2.1
ATM Addressing for LAN Emulation
The SmartCell 6A000 provides a default format for ATM addresses used by LAN emulation. The default format is 
constructed as follows:
netprefix + the MAC address of the device + a Selector Byte
Where the netprefix is constructed from
39 + nine zero bytes + the last three bytes of the switch's MAC address
The Selector Byte specifies to whom the ATM address belongs.
00 = LEC
01 = LECS 
02 = LES or BUS
For instance, if the switch's MAC address is 00:20:D4:14:41:80, then the 20-byte ATM address of the LECS is:
39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:80:01
Where
39:00:00:00:00:00:00:00:00:00:14:41:80 = netprefix
00:20:D4:14:41:80 = the switch's MAC address
01 = the Selector Byte indicating that this is the LECS
Additionally, within both the LES and BUS addresses, the byte that corresponds to the last byte of the MAC address 
is summed with the ELAN number. For example, the ATM address of the LESs on ELAN000, ELAN001, and 
ELAN010 are
LES for ELAN000 = 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:80:02
LES for ELAN001 = 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:81:02
LES for ELAN010 = 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:8A:02