General Configuration Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
5-47
3.
Press ENTER. If the subnet mask is valid, the cursor returns to the 
beginning of the Subnet Mask field. If the entry is not valid, the Event 
Message Line displays “INVALID SUBNET MASK OR FORMAT 
ENTERED”. Local Management does not alter the current value, but 
it does refresh the Subnet Mask field with the previous value.
4.
Use the arrow keys to highlight the SAVE command, then press 
ENTER. The warning screen shown in 
 displays.
5.
Use the arrow keys to highlight the YES command and press ENTER. 
The changes are saved and the module reboots
5.15.3
Setting the Default Gateway
If the SNMP management station is located on a different IP subnet than 
the 6E12X-26 and 6E13X-25, a default gateway must be specified. When 
an SNMP Trap is generated, the 6E12X-26 and 6E13X-25 sends the Trap 
to the default gateway. To set the default gateway, perform the following 
steps:
1.
Use the arrow keys to highlight the Default Gateway field.
2.
Enter the IP address of the default gateway using the DDN format.
For example: 134.141.79.121
3.
Press ENTER. If the default gateway entered is a valid format, the 
cursor returns to the beginning of the Default Gateway field. If the 
entry is not valid, the Event Message Line displays “INVALID 
DEFAULT GATEWAY OR FORMAT ENTERED”. Local 
Management does not alter the current value, but it does refresh the 
Default Gateway field with the previous value.
4.
Use the arrow keys to highlight the SAVE command.
5.
Press ENTER. The Event Message Line at the top of the screen 
displays “SAVED OK”.