DELL PC2748 User Manual
26
to Managed Mode. The chapter "Starting and Configuring the Dell™PowerConnect™
2708/2716/2724/2748 for Managed Mode Operation" explains how to set the switch to Managed
Mode.
Site Requirements
The PowerConnect 2708/2716/2724/2748 devices can be mounted in a standard equipment rack,
placed on a tabletop, or mounted on the wall.
Before installing the unit, verify that the site selected for the device meets the following site
Before installing the unit, verify that the site selected for the device meets the following site
requirements:
•
Power — The device is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet
220/110 VAC, 50/60 Hz. If the device has two power supplies, the site should have two power
outlets with different power feeders.
•
General — Ensure that the power supply is correctly installed.
•
Clearance — There is adequate frontal clearance for operator access. Allow clearance for
cabling, power connections, and ventilation.
•
Cabling — Cabling is routed to avoid sources of electrical noise such as radio transmitters,
broadcast amplifiers, power lines, and fluorescent lighting fixtures.
•
Ambient Requirements — The ambient unit operating temperature range is 0 to 45C (32 to
113F) at a relative humidity of up to 95%, non-condensing. Verify that water or moisture
cannot enter the device case.
Unpacking
NOTE:
Before unpacking the device, inspect the packaging and report any evidence of damage
immediately to Dell.
Safety
CAUTION:
Never remove the cover on a power supply or any part that has the following label
attached.
Figure 3-1. Caution Label
CAUTION:
Hazardous voltage, current, and energy levels are present inside any component that has
this label attached. There are no serviceable parts inside these components. If you suspect a problem
with one of these parts, contact a service technician.
with one of these parts, contact a service technician.