DELL PC2748 User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
63
Optical Transceivers Diagnostics
The Optical Transceivers Diagnostics page contains fields for performing tests on Fiber Optic
cables. The optical transceiver provides access to a set of parameters that can be monitored and
displayed to the system administrator.
NOTE:
The
Optical Transceivers Diagnostics analysis applies only to PowerConnect 2724
device’s SFP ports, which support the digital diagnostic standard SFF-4872.
To open the page, click
Optical Transceivers Diagnostics in the tree view.
Figure 6-14. Optical Transceivers Diagnostics
Port — The port on which the cable is tested.
Temperature — Internally measured transceiver temperature.
Voltage — Internally measured supply voltage.
Current — Measured TX bias current.
Output Power — Measured TX output power in milliwatts.
Input Power — Measured RX power in milliwatts.
Transmitter Fault — TX fault
Loss of Signal — Indicates if a loss of signal (LOS) occurred in the cable.
Data Ready — Indicates that the optical transceiver has achieved power up and data is ready.
Temperature — Internally measured transceiver temperature.
Voltage — Internally measured supply voltage.
Current — Measured TX bias current.
Output Power — Measured TX output power in milliwatts.
Input Power — Measured RX power in milliwatts.
Transmitter Fault — TX fault
Loss of Signal — Indicates if a loss of signal (LOS) occurred in the cable.
Data Ready — Indicates that the optical transceiver has achieved power up and data is ready.
Displaying Optical Transceivers Diagnostics Test Results
1
Open the Optical Transceiver Diagnostics page.
2
Select an optic cable interface to be tested.