DELL PC2748 User Manual

Page of 84
63
Optical Transceivers Diagnostics
The Optical Transceivers Diagnostics page contains fields for performing tests on Fiber Optic 
cables. The optical transceiver provides access to a set of parameters that can be monitored and 
displayed to the system administrator.
 
NOTE: 
The 
Optical Transceivers Diagnostics analysis applies only to PowerConnect 2724 
device’s SFP ports, which support the digital diagnostic standard SFF-4872.
To open the page, click 
Optical Transceivers Diagnostics in the tree view.
Figure 6-14. Optical Transceivers Diagnostics
Port — The port on which the cable is tested.
Temperature — Internally measured transceiver temperature.
Voltage — Internally measured supply voltage.
Current — Measured TX bias current.
Output Power — Measured TX output power in milliwatts.
Input Power — Measured RX power in milliwatts.
Transmitter Fault — TX fault
Loss of Signal — Indicates if a loss of signal (LOS) occurred in the cable.
Data Ready — Indicates that the optical transceiver has achieved power up and data is ready.
Displaying Optical Transceivers Diagnostics Test Results
1
Open the Optical Transceiver Diagnostics page.
2
Select an optic cable interface to be tested.