Panasonic PT-F300N User Manual

Page of 69
57
Using WebBrowser 
(cont.)
This page indicates the projector status.
If you migrate from other pages, click [Monitor information] in the main menu (left of the screen).
Monitor information window
The monitor information is refreshed at fixed intervals, but the current exact information can be checked by clicking [View] → 
[Refresh].
 Monitored information
On this window, click the [Status information] tab.
 Network information
On this window, click the [Network status] tab.
If [SELF TEST Error (Detail)] appears on the monitored 
information window, click it to view the error details.
If [FAILED] appears
Item
Description
MAIN CPU BUS
There is a problem with a microcontroller circuit. Contact your dealer.
FAN
There is a problem with the fan or fan drive circuit. Contact your dealer.
INPUT AIR TEMPERATURE  
Input air temperature is high. The projector is likely being used in a high temperature 
environment such as near heating equipment.
OUTPUT AIR TEMPERATURE
Temperature surrounding the lamp is high. The exhaust vent is likely blocked.
LAMP REMAIN TIME
The lamp has been used for longer than its rated useful life, and it is time to replace it.
LAMP STATUS
The lamp could not be lit. 
Allow the bulb of the light source to cool, and then turn on the projector.
INPUT AIR TEMP.SENSOR
There is a problem with the air intake temperature sensor. Contact your dealer.
OUTPUT AIR TEMP.SENSOR
There is a problem with the exhaust temperature sensor. Contact your dealer.
BATTERY
The battery must be replaced. Contact your dealer.
ACF UNIT
Either the ACF unit is not set properly or it does not work. For further detail, see the 
instruction manual for the projector.
FILTER REMAIN
The remaining filter gets low. For further detail, see the instruction manual for the 
projector.