Input cord length
DC INPUT: User supplies cabling. 10 gauge or larger (see manual). AC INPUT: user supplies hardwire input cabling
Recommended
Electrical Service
DC INPUT: Requires 48VDC input source capable of delivering 56A for the required duration (when used at full
continuous capacity - DC requirements increase during Over-Power and Double-Boost operation). For automotive
applications, professional hardwire i
Maximum input
amps / watts
DC INPUT: Full continuous load - 56A at 48VDC. AC INPUT: 33 amps at 120VAC with full inverter and charger load (13A
max charger-only / combined input load to support charger and AC output is automatically controllable to 66%-33%-0%
based on AC output load
BATTERY
Expandable
battery runtime
Runtime is expandable with any number of user supplied wet or gel type batteries
DC system voltage
48V
Battery recharge
rate
15A
LEDS ALARMS & SWITCHES
Front panel LEDs
Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7
levels reported). See manual for sequences.
Switches
3 position on/off/remote switch enables simple on/off power control plus "auto/remote" setting that enables distant on/off
control of the inverter system when used in conjunction with optional APSRM4 accessory when used in inverter mode. In
AC uninterruptible power mode, "auto/remote" setting enables automatic transfer from line power to battery power - to
maintain continuous AC power to connected loads.
PHYSICAL
Shipping weight
(lbs)
43
Shipping weight
(kg)
19.5
Shipping
Dimensions
(HWD/in)
13.5 x 15 x 21.5
Shipping
Dimensions
(HWD/cm)
34.3 x 38.1 x 54.6
Unit weight (lbs)
38.6
Unit weight (kg)
17.5
Unit Dimensions
(HWD/in)
7.25 x 8.5 x 16
Unit Dimensions
(HWD/cm)
18.4 x 21.6 x 40.6
Material of
construction
Polycarbonate
Form factors
supported
Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting
information)
Cooling method
Multi-speed fan
Style
Heavy-duty with built-in battery charger
ENVIRONMENTAL
Relative Humidity
0-95% non-condensing
Operating
Temperature
32-104 Fahrenheit / 0-40 Celcius
LINE / BATTERY TRANSFER
Transfer time from
line power to
battery mode
8 milliseconds (typical - compatible with many computers, servers and networking equipment - verify transfer time
compatibility of loads for UPS applications)
Low voltage
transfer to battery
power
In AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 75V (user adjustable to 85, 95, 105V
- see manual)