Reading the Front Panel Indicators
17
Reading the Front Panel Indicators
Green POWER LED
The 
POWER
 LED is on when the inverter is connected to DC 
power and the inverter is switched On.
Red FAULT LED
The 
FAULT
 LED comes on for one of the following reasons:
See 
 for further 
details about the 
FAULT
 LED.
Condition
Cause / Action
Over Temperature 
Shutdown
The PROwatt 600 has overheated and shut 
down. The inverter may have overheated 
because it was operated at power levels 
above its 600W continuous output rating or 
because it was installed in a location that 
does not allow it to dissipate heat properly.
Turn the inverter off and then back on after 
it has cooled down.
Note:
 To cool the inverter quickly, remove 
any loads, and leave the switch on to keep 
the fan running.
Overload Shutdown A severe overload has caused the 
PROwatt 600 to shut down.
Turn it off for 4–5 seconds, correct the fault 
condition, and turn it back on. Do not turn 
the inverter on again unless you have 
corrected the fault condition (removed the 
load or unplugged it).
Low Voltage 
Shutdown
The supply voltage (battery) has dropped 
below 10 V.
High Voltage 
Shutdown
The supply voltage (battery) has exceeded 
15 V.