Schumacher PSJ-2212 Leaflet

Page of 2
THIS PRODUCT HAS A SEALED LEAD-ACID BATTERY INSIDE THAT SHOULD BE KEPT AT FULL CHARGE FOR LONGER LIFE.
RECHARGE WHEN FIRST RECEIVED, AFTER EACH USE AND EVERY 3 MONTHS.
IMPORTANT SAFETY INSTRUCTIONS
Save These Instructions
important safety instructions
Someone should be within range of your voice or close enough to 
come to your aid when you are working near a lead-acid battery.
Have  plenty  of  fresh  water  and  soap  nearby  in  case  battery  acid 
contacts skin, clothing, or eyes. If acid enters the eye area, rinse 
with  cold  water  for  at  least  10  minutes  and  get  medical  help 
immediately.
Do not smoke, or use matches or cigarette lighters, or allow any spark 
or flame near the battery or engine.
Never operate the power source unit if it has damaged lead wire or 
clamps. Have the lead wire replaced by a qualified technician.
Wear complete eye and clothing protection when working with lead-
acid batteries.
Do not permit internal battery in the jump starter to freeze. Never 
charge a frozen battery.
handling warning
WARNING: Handling the cord on this product or cords associated with 
this product, may expose you to lead, a chemical known to the State 
of California to cause cancer and birth defects or other reproductive 
harm. Wash hands after handling.
operating instructions
Warning:  Failure  to  follow  instructions  may  cause 
damage or an explosion. Read entire instruction manual 
before use.
1.  Turn ignition off before making cable connections.
2.  Use in a well-ventilated area.
3.  Keep clear of fan blades, belts, pulleys and other parts that may 
cause injury.
4.  Make sure the rotary power switch on the front panel is in the o 
(off) position until clamps are connected to the vehicle battery.
If plugged into an 110V AC wall outlet, disconnect.
5.  To prevent sparking, NEVER allow clamps to touch together or 
to contact the same piece of metal.
6.  Clamp the red clamp (+) to the positive terminal of the battery. 
(for a negative grounded system.)*
7.  Clamp the black clamp (-) to an unpainted and unmoving part 
of the chassis or engine block. The 3-digit display will show the 
voltage of the battery. 
8.  If you have connected the clamps backwards, an audio alarm 
will sound. Do NoT turn your jump starter on. This could cause 
serious damage. Reverse the connections, and the audio alarm 
will stop.
9.  If no audio alarm sounds, turn the rotary switch to the 12V position. 
(or, for Model PSJ-4424, switch to 12V or 24V.) The clamps are 
now powered. Crank the engine. If the engine does not start within 
5 – 8 seconds, stop cranking and wait at least 1 minute before 
attempting to start vehicle again. (This permits the battery to cool 
down.)
 
NOTE: When the voltage on the clips exceeds 15 volts, the audio 
alarm will beep four times. If the cables are connected to a 24-volt 
system when the switch is in the 12V position, the audio alarm 
will sound continuously. TURN off the jump starter immediately 
or internal battery damage will occur.
 
NOTE: If the switch is in the 12V or 24V position or the jump 
starter is connected to a battery for more than 5 minutes, four 
beeps will sound.  This is a reminder to turn the jump starter off 
and/or disconnect from battery when it is not in use.
10.  After the engine starts, turn the rotary switch to the o (off) 
position. Then disconnect the black clamp (-) and then the red 
clamp (+) in that order. Store the clamps in the compartments 
located on the sides of the case.
11.  Recharge the jump starter as soon as possible after use.
 
*NOTE:  In  the  rare  case  of  jump-starting  a  vehicle  that  has 
a  positive-grounded  vehicle  electrical  system,  connect  the 
NEGATIVE  black  clamp  (-)  to  the  negative  terminal  (-)  of  the 
vehicle battery. Then connect the PoSITIVE red clamp (+) to an 
unpainted and unmoving part of the vehicle chassis or engine 
block. If you are unsure of the nature of the vehicle’s electrical 
grounding system, check the owner’s manual of the vehicle. To 
disconnect clamps, reverse order.
digitial display 
The  display  can  be  used  to  indicate  a  battery’s  voltage  when 
connected  to  a  battery  or  the  percentage  of  charge  in  the  jump 
starter’s internal battery.
With  the  switch  in  the  off  position,  connect  the  clamps  to  the 
vehicle’s battery and its voltage is displayed. Turn the jump starter’s 
rotary switch to 12V, (or, for Model PSJ-4424, 12V or 24V) and the 
combination of both internal and external batteries are shown.
To read the internal battery’s charge status: Press the display button 
to read the percentage of charge left in the internal battery. A fully 
charged battery will read 100%.
charging  of  internal  battery  with  built-in  3-amp,  automatic 
charger.
After  removing  the  jump  starter  from  the  carton,  charge  it  for  a 
minimum of 8 hours before using.
1.  Make sure the rotary power switch on the front panel is in the o 
(off) position.
2.  Plug  extension  cord  into  charger  plug  on  the  left  side  of  the 
jump starter. (Extension cord not included; must be purchased 
separately.)
3.  Plug the extension cord into 110V AC electrical wall outlet.
4.  Charging of the internal battery could take up to 48 hours due to 
age and condition of the battery. At full charge, the charger will 
automatically drop into a float mode and maintain the battery at 
full charge without damaging the battery. The jump starter can 
be left plugged into the 110V wall outlet indefinitely to maintain 
full power.
00-99-000686/0906
InstRuctIon Manual
Jump starter & Dc Power source
Models:   PSJ-2212  One 22-Ah Battery   12V
 
PSJ-3612  Two 18-Ah Batteries  12V
 
PSJ-4424  Two 22-Ah Batteries  12/24V