Hitachi SJ300 Series User Manual
SJ300 Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–65
“P” Group: Expansion Card Functions
The two (optional) expansion cards for the SJ300 have associated configuration data. The
following table defines the functions and their value ranges. Please refer to the expansion card
manual for more details.
following table defines the functions and their value ranges. Please refer to the expansion card
manual for more details.
“P” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(EU)
–FU
(US)
–FR
(JP)
(JP)
P001
Operation mode on
expansion card 1 error
expansion card 1 error
Two option codes:
00 Trip (stop motor)
01 Continuous operation
00 Trip (stop motor)
01 Continuous operation
✘ ✔
00
00
00
—
>P001 OPTION1
SELECT TRP
P002
Operation mode on
expansion card 2 error
expansion card 2 error
Two option codes:
00 Trip (stop motor)
01 Continuous operation
00 Trip (stop motor)
01 Continuous operation
✘ ✔
00
00
00
—
>P002 OPTION2
SELECT TRP
P010
Feedback option enable
Two option codes:
00 Disable
01 Enable
00 Disable
01 Enable
✘ ✘
00
00
00
—
>P010 FEEDBACK
SELECT OFF
P011
Encoder pulse-per-
revolution (PPR) setting
revolution (PPR) setting
Range is 128 to 65000
pulses per revolution
pulses per revolution
✘ ✘ 1024 1024 1024 pulse
>P011 FEEDBACK
ENC-P 01024pls
P012
Control pulse setting
Selects between automatic
speed regulation (ASR) and
automatic position regula-
tion (APR) modes.
Two option codes:
00 ASR mode
01 APR mode
speed regulation (ASR) and
automatic position regula-
tion (APR) modes.
Two option codes:
00 ASR mode
01 APR mode
✘ ✘
00
00
00
—
>P012 FEEDBACK
CONTROL ASR
P013
Pulse input mode setting Pulse input mode setting.
Three option codes:
00 quadrature
01 count and direction
02 separate forward and
00 quadrature
01 count and direction
02 separate forward and
reverse pulse trains
✘ ✘
00
00
00
—
>P013 FEEDBACK
PULSE MD0
P014
Home search stop
position setting
position setting
Range is 0 to 4095 pulses
✘ ✔
0.
0.
0.
—
>P014 FEEDBACK
POS 0000pls
P015
Home search speed
setting
setting
Range is 0.00 to 99.99 /
100.0 to 120.0Hz
100.0 to 120.0Hz
✘ ✔ 5.00 5.00 5.00
Hz
>P015 FEEDBACK
FC 005.00Hz
P016
Home search direction
setting
setting
Two option codes:
00 Forward
01 Reverse
00 Forward
01 Reverse
✘ ✘
00
00
00
—
>P016 FEEDBACK
TURN FW
P017
Home search comple-
tion range setting
tion range setting
Range is 0 to 10,000 pulses
✘ ✔
5
5
5
pulse
>P017 FEEDBACK
L 00005pls
P018
Home search comple-
tion delay time setting
tion delay time setting
Range is 0.00 to 9.99
seconds
seconds
✘ ✔ 0.00 0.00 0.00
sec.
>P018 FEEDBACK
TW 000.00s
P019
Electronic gear set
position selection
position selection
Two option codes:
00 Position feedback side
01 Position command side
00 Position feedback side
01 Position command side
✘ ✔
00
00
00
—
>P019 FEEDBACK
EGRP FB
P020
Electronic gear ratio
numerator setting
numerator setting
Range is 1 to 9999
✘ ✔
1.
1.
1.
—
>P020 FEEDBACK
EGR-N 00001
P021
Electronic gear ratio
denominator setting
denominator setting
Range is 1 to 9999
✘ ✔
1.
1.
1.
—
>P021 FEEDBACK
EGR-D 00001