Seiko Instruments DPU-30 User Manual

Page of 84
 
4-1
 
CHAPTER 4 
 
INTERFACE 
 
 
This chapter describes information that is required when using the printer connected to a host, such 
as the serial and parallel interface specifications. 
 
4.1  CONNECTOR TERMINAL LAYOUT 
 
1.  Interface and power connector terminal layout 
 
Connector (plug) : XG4A-4032(Omron) 
Connector signal layout 
 
39
40
 
 
(!signal name indicates Active Low.) 
 
Table 4-1    Connector Terminal Assignment 
No. Signal 
name 
Direction 
Description 
!STROBE 
In 
Parallel data input 
2 to 9 
DATA0 to 7 
In 
High:1, Low:0 
10 !ACK  Out 
Acknowledge 
11 
BUSY 
Out 
Busy to read 
12 PE  Out 
Paper 
empty 
13 
SEL OUT 
Out 
Online High 
14 !ERROR  Out 
Error 
15 
!RESET 
In 
Reset (Valid in Low 20ms) 
16 
TxD 
Out 
Serial data ouput 
17 
RxD 
In 
Serial data input 
18 
RTS 
Out 
RS-232C Request to send 
19 
CTS 
In 
RS-232C Clear to send 
20 
NEAR_A 
Out 
Paper near end 
⋅ A (+) 
21 
NEAR_C 
In 
Paper near end 
⋅ C (+) 
22 NEAR_K 
− 
Paper near end 
⋅ K (−) 
23 NEAR_E 
− 
Paper near end 
⋅ E (−) 
24 
NEAR_OUT 
Out 
Paper near end signal 
25 !FEED_IN  In Feed 
signal 
26 GND 
− Ground 
27 
SEL_LED+ 
Out 
SEL LED on (
+) 
28 
SEL_LED- 
Out 
SEL LED on (
−) 
29 to 34 
V+ 
− Power 
(
+) 
35 to 40 
V
− 
− Power 
(
−) 
∗ Connect to all the No.29 to 34 and No.35 to 40 terminal when supplying the power