Epson EB-Z11000W User Manual
• Projector input port name: RS-232C
<At the projector>
<At the computer>
<At the projector>
(PC serial cable)
<At the computer>
Signal Name
Function
GND
Signal wire ground
TD
Transmit data
RD
Receive data
Communications protocol
• Default baud rate setting: 9600 bps
• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
About PJLink
PJLink Class1 was established by the JBMIA (Japan Business Machine and
Information System Industries Association) as a standard protocol for
controlling network-compatible projector's as part of their efforts to
standardize projector control protocols.
Information System Industries Association) as a standard protocol for
controlling network-compatible projector's as part of their efforts to
standardize projector control protocols.
The projector complies with the PJLink Class1 standard established by the
JBMIA.
JBMIA.
You need to make network settings before you can use PJLink. See the
following for more information on network settings.
following for more information on network settings.
s
It complies with all commands except for the following commands defined
by PJLink Class1, and agreement was confirmed by the PJLink standard
adaptability verification.
by PJLink Class1, and agreement was confirmed by the PJLink standard
adaptability verification.
URL:
• Non-compatible commands
Function
PJLink Command
Mute settings
Image muting set
AVMT 11
Audio muting set
AVMT 21
• Input names defined by PJLink and corresponding projector sources
Source
PJLink Command
Computer
INPT 11
BNC
INPT 13
Video
INPT 21
S-Video
INPT 22
DVI-D
INPT 31
HDMI
INPT 32
Monitoring and Controlling