Barco 3G/HD/SD-SD User Manual

Page of 33
MatrixPRO-II 3G/HD/SD-SDI Routers 
 
Rev. 1.1 
 
 
 
MatrixPRO-II HD/3G SDI Series –User’s Guide - Rev. 1.1 
21 
5
 
Router communication 
You  gain  access  to  router  for  communication  purposes  by  connecting  either  the  router’s 
serial port to your computer or by using an Ethernet connection. 
Do  not  use  both  the  router’s  Ethernet  port  and  RS-232  serial  port  at  the  same 
time. Doing so may cause loss of important communication and control data. 
5.1
 
Serial connection 
Connection can by be made through the serial port(s) of the router;  
The communication parameters are configurable. Please refer to the protocol documentation 
of the appropriate communication/control protocol. 
Example: The protocol parameters s are as follows: 
 
Bit rate 19200 bit/s 
 
Data bits 8 bits 
 
Stop bits 1 
 
Parity: No parity 
The DB9 female connector for the serial port(s) of the router has the following pin-out: 
Pin # 
RS-232 mode 
Not in use 
Tx 
Rx 
Not in use 
GND 
GND 
RTS 
CTS 
Do Not Connect! 
Note that if the standard RS-232 cable specification (DCE) is followed: 
A cable with Male+Male or Female+Female connectors at the cable ends is used 
for Rx/Tx crossed connection, and 
A  cable  with  Male+Female  connectors  at  the  cable  ends  is  used  for  a  straight 
through connection. 
5.1.1
 
Maximum cable length (RS-232) 
IEEE  has  specified  the  maximum  cable  length  for  an  RS-232  connection  to  15m.  Longer 
distances can be installed depending on the environmental conditions of the installation site.