AudioQuest M-27 User Manual

Page of 25
 
 
Switch Positions 
 
Switch 1 and 2 select the M-27 functions. 
 
Switch 1 and 2 are read only on RESET and when the battery is replaced. 
 
Switch 3 selects printer options. 
 
Switch 3 is read at the start of each printout and may be changed without destroying data.
 
SWITCH 1
 
Position 1         On = "C" weighting               Off = "A"
 
Position 2         On = 30 dB Range                 Off = 50 dB Range
 
Position 3 In 30 dB Range
 
                         On = 115 dB U.L.                  Off = 90 dB U.L.
 
In 50 dB Range
 
                         On = 140 dB U.L.                  Off = 115 dB U.L.
 
Position 4        On = Fast                             Off = Slow
 
Positions        5         6         Criterion Level
 
                      Off     Off     =80 dB
 
                      Off     On     =84 dB
 
                      On      Off    =85 dB
 
                      On     On      =90 dB
 
 
Positions         7       8         Exchange Rate
 
                       Off    Off   = 3 dB
 
                       Off    On    = 4 dB
 
                       On     Off   = 5 dB
 
                       On     On   = 6 dB 
 
SWITCH 2
  
  
  
  
  
  
  
Positions         1
  
2
  
3
  
4
  
HTL
  
LTL
  
Off
  
Off
  
Off
  
Off
  
= 70
  
dB
  
none
  
Off
  
Off
  
Off
  
On
  
- 70
  
dB
  
none
  
Off
  
Off
  
On
  
Off
  
= 75
  
dB
  
none
  
Off
  
Off
  
On
  
On
  
= 80
  
dB
  
none
  
Off
  
On
  
Off
  
Off
  
= 85
  
dB
  
none
  
Off
  
On
  
Off
  
On
  
= 90
  
dB
  
none
  
Off
  
On
  
On
  
Off
  
- 75
  
dB
  
70 dB
  
Off
  
On
  
On
  
On
  
= 80
  
dB
  
70 dB
  
On
  
Off
  
Off
  
Off
  
= 85
  
dB
  
70 dB
  
On
  
Off
  
Off
  
On
  
= 90
  
dB
  
70dB
  
On
  
Off
  
On
  
Off
  
= 80
  
dB
  
75 dB
  
On
  
Off
  
On
  
On
  
= 85
  
dB
  
75 dB
  
On
  
On
  
Off
  
Off
  
= 90
  
dB
  
75 dB
  
On
  
On
  
Off
  
On
  
= 85
  
dB
  
80 dB
  
On
  
On
  
On
  
Off
  
= 90
  
dB
  
80 dB
  
On
  
On
  
On
  
On
  
= 90
  
dB
  
85 dB
  
Position 5       On =
  
24 hour
  
Off
  
= 12
  
hour
  
Position          6
  
7
  
8
  
Unit
  
Off
  
Off
  
Off
  
= 0
  
  
  
  
Off
  
Off
  
On
  
= 1
  
  
  
  
Off
  
On
  
Off
  
= 2
  
  
  
  
Off
  
On
  
On
  
= 3
  
  
  
  
On
  
Off
  
Off
  
= 4
  
  
  
  
On
  
Off
  
On
  
= 5
  
  
  
  
On
  
On
  
Off
  
= 6
  
  
  
  
On
  
On
  
On
  
= 7
  
  
  
  
 
SWITCH 3
 
Position 1       On = Busy    
     Off = Data Set Ready 
 
 
 
               handshake
 
Position 2       On = Parallel printer       Off = Serial printer 
 
Normally positions 1 and 2 are set the same.