Sony BKS-R1601 User Manual

Page of 158
5-49
ROUTING SWITCHER SYSTEM (E)
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only)
SET MONITOR FUNCTION    DVS-V6464B Monitor Bus I/F V2.10 STATION NUMBER 23
                       MODIFICATION COMMAND
      M: SET AVAILABLE MONITOR LINE INPUT=( ENABLE )OUTPUT=( ENABLE )
                                           Ctrl-Z:RETURN
MONITOR SYSTEM SETUP MENU.        BKS-R3204 V3.10 STATION NUMBER 6
                          Station Number ?
  Ctrl-E:MENU     Ctrl-Z:RETURN
Cascade
Cascade
Input Monitor
Output
Monitor
Output
Monitor
Cascade
Cascade
Input Monitor
128
65
64
1
1
64
65
128
E
D
DVS-V6464B
D
DVS-V6464B
DVS-V6464B
DVS-V6464B
E
E
E
E : Enable
D : Disable
5-4. Setting Items of the Secondary
Station on Monitor S-BUS
(BKDS-V3293B only)
M: SET AVAILABLE MONITOR LINE
(DVS-V3232B/V6464B 
+
+
+
+
+
 BKDS-R3292B)
Menu Screen of the Secondary Station on Monitor S-BUS
(DVS-V3232B/V6464B)
Purpose
This menu is used to set the input monitor and output
monitor to valid or invalid.
Setting Procedure
1.
Select menu item [M].
2.
Select the source/destination using the cursor, and
press [Enter] to change the setting. (“ENABLE” 
“DISABLE” 
 “ENABLE”)
3.
Press [Ctrl] 
_ [Z] to display the menu screen of the
primary station on the monitor S-BUS.
n
Be sure to set the monitor line to “DISABLE” in cascade
connection.
If set to “ENABLE”, the monitor may not be performed
properly.
L : COPY TABLE DATA <MONITOR MENU>
Purpose
This menu is used to copy the setting contents of the
remote control unit.  This is applied to BKS-R3204 and
BKS-R3205.
Setting Procedure
1.
Select menu item [L].  This item can be selected from
both the menu and another setting screen.
2.
The message “Station Number?” will be displayed.
Enter the station number to be copied.
3.
When [Enter] is pressed, the table data will be copied
and the screen will return to the setting screen.
When [Ctrl] 
_ [E] is pressed again, the menu screen
of the secondary station on the monitor S-BUS will be
displayed.
4.
When [Ctrl] 
_ [Z] is pressed, menu screen of the
primary station on the monitor S-BUS will be dis-
played.
Example of Setting Screen
Data set on the menu item [N : SET PANEL TABLE] are
copied.