5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only)
MONITOR SYSTEM SETUP MENU         BKS-R3210 V1.10      STATION NUMBER 6
 SOURCE
     name    Description            name    Description
   1 IN001   CAM001               2 IN002   CAM002
   3 IN003   CAM003               4 IN004   CAM004
   5 IN005   VTR005               6 IN006   VTR006
   7 IN007   VTR007               8 IN008   VTR008
   9 IN009   ONAIR01             10 IN010   ONAIR02
  11 IN011   ONAIR03             12 IN012   ONAIR04
  13 IN013   STADIO1             14 IN014   STADIO2
  15 IN015   STADIO3             16 IN016   STADIO4
  17 IN017   MONI001             18 IN018   MONI002
  19 IN019   IN019               20 IN020   IN020
  21 IN021   IN021               22 IN022   IN022
  23 IN023   IN023               24 IN024   IN024
  25 IN025   IN025               26 IN026   IN026
  27 IN027   IN027               28 IN028   IN028
  29 IN029   IN029               30 IN030   IN030
  31 IN031   IN031               32 IN032   IN032
  Ctrl-E:MENU  Ctrl-D:RETURN  Right:DESTINATION  Left:SOURCE
MONITOR SYSTEM SETUP MENU          BKS-R3210 V1.10     STATION NUMBER 6
 DESTINATION
     name    Description            name    Description
   1 OUT001  DST001               2 OUT002  DST002
   3 OUT003  DST003               4 OUT004  DST004
   5 OUT005  DST005               6 OUT006  DST006
   7 OUT007  DST007               8 OUT008  DST008
   9 OUT009  OUT009              10 OUT010  OUT010
  11 OUT011  OUT011              12 OUT012  OUT012
  13 OUT013  OUT013              14 OUT014  OUT014
  15 OUT015  OUT015              16 OUT016  OUT016
  17 OUT017  OUT017              18 OUT018  OUT018
  19 OUT019  OUT019              20 OUT020  OUT020
  21 OUT021  OUT021              22 OUT022  OUT022
  23 OUT023  OUT023              24 OUT024  OUT024
  25 OUT025  OUT025              26 OUT026  OUT026
  27 OUT027  OUT027              28 OUT028  OUT028
  29 OUT029  OUT029              30 OUT030  OUT030
  31 OUT031  OUT031              32 OUT032  OUT032
  Ctrl-E:MENU  Ctrl-D:RETURN  Right:DESTINATION  Left:SOURCE
*
1: Applicable to BKS-R3210 only.
*
2: Applicable to BKS-R1607 only.
*
3: When monitor S-BUS is used, select STAND ALONE= Stand alone
machine at all times since mother-daughter setting is not necessary.
n
In BKS-R1607/R1608/R3209/R3210 of version V1.10 and
higher, the 160 description names that are transferred from
the primary station can be registered in the range of inputs
512 
x outputs 512 in the order of terminal number regard-
less of the block number.  When you want to use more than
160 of the description names, transmit the names from the
primary station after dividing the description names into
several blocks.
The following operations are possible from the screen.
Look at destination from source side : [*] key
Look at source from destination side : [&] key
Return to the previous page :
[(] key
Move to the next page :
[)]
 key
Example of Setting Screen
Example of Setting Screen
Z : SET PANEL STATUS (BKS-R1607/R1608/
R3204/R3205/R3209/R3210)
<MONITOR MENU>
Purpose
Set the various modes of the remote control unit.
Number of sources and destinations that can be controlled
from the remote control unit, can be expanded by connect-
ing multiple mother and daughter panels.  Setting the
mother and daughter panels are also performed using this
menu.  (Ten mother panels can be registered at the maxi-
mum.)
The setting contents are as follows.
DISPLAY MODE
STATUS= Displays the status of the primary station
crosspoint table.
PROMPT= The pressed buttons lit immediately.
PROTECT MODE
ON AIR= Execute switching from the panel even during
the protect mode.
NORMAL= Switching is not possible during the protect
mode.
PHANTOM PROTECT
PART PROT= Execute switching on the phantom on
which protect is not set.
FULL PROT=Switching is not executed on all phantoms
when any of the phantom is set to PRO-
TECT ON.
BUTTON LINK= Switching is not executed on all
phantoms when the PROTECT button
on the panel is set to ON.
PANEL MODE
*3
STAND ALONE= Stand alone panel
MOTHER= Mother panel
DAUGHTER= Daughter panel
PANEL LAYOUT
*1
TYPE + NUM.= Selecting X-Y
DIRECT= Selecting direct
LEVEL MODE
*1
SINGLE= Selecting a single level
MULTI= Selecting multiple levels
DEST SELECTION
*2
DISABLE=The destination change from panel is
disabled.
ENABLE=The destination change from panel is enabled.