Sony BKS-R1601 User Manual

Page of 158
5-56
ROUTING SWITCHER SYSTEM (E)
5-7. Initialization of Table Data
HDS-V3232 :
Initializing Procedure
Corresponding Menu Items
1
1. Set the test switch (S2) on the CPU-251 board to “D”.
All items of the primary and secondary stations.
2. Press the reset switch (S8).
2
1. Set the test switch (S2) on the CPU-251 board to “C”.
[W : SYSTEM STATUS LOG]
2. Press the reset switch (S8).
3
Select the menu item [K : RESET TO DEFAULT TABLE]
All items of the primary station excluding the
of the primary station and  press 
[Y]
.
following 4 items.
.
[H : SET GLOBAL PHANTOM]
.
[N : SET DESCRIPTION NAME GROUP]
.
[O : SET TIE LINES]
.
[W : SYSTEM STATUS LOG]
4
Select the menu item [K : reset To default table]
All items of the secondary  station excluding
of the secondary  station and press 
[Y]
.
the crosspoint data.
5
Select the menu item [U : SELECT REMOTE PROTOCOL]
[U : SELECT REMOTE PROTOCOL]
of the secondary station and press 
[F2]
 (DEFAULT).
n
The primary station of HDS-V3232 does not have the menu item[S].
The secondary station of the menu item [Z] of [SWITCHING FIELD] only.
5-7-2. Default Values Initialization
Item
Default Value
Primary station
[B : SET SOURCE/DEST TYPE]
TYPE : 0=IN, 1=OUT, 2-F=None
NAME : IN001-IN512, OUT001-OUT512
[E : SET LEVEL TABLE]
All levels of all destination is ENABLE
Level name : 1, 2, 3....7, 8
[F : SET ACTIVE UNIT NUMBER]
DVS-V3232B : STATION 2-33 ENABLE
DVS-V6464B : STATION 2-65 ENABLE
[H : SET GLOBAL PHANTOM]
Not set
[J : NAME STYLE]
Type 
+
 Num (“Type 
+
 Number” name mode)
[L : SET PHYSICAL ASSIGNMENT]
Physical location number=Virtual  location number
[M : SET INHIBIT TABLE]
Not set
[N : SET DESCRIPTION NAME GROUP]
[O : SET TIE LINES]
[P : CHANGE PASSWORD]
[S : SELECT INDICATION COLOR]
OFF
[U : SELECT CONTROL MODE]
All channels : DIRECT
[V : SELECT WARNING DISPLAY]
OFF
[W : SYSTEM STATUS LOG]
NO LOG
[Z : SET UNIT  DETECTABLE]
All STATION : OFF
Secondary station
[A : SET UNIT  LOCATION ]
No OFFSET
[U : SELECT REMOTE PROTOCOL]
The input /output number is 1:1.
[Z : SELECT SDI FORMAT]
4:2:2, SWITCHING FIELD=FIELD
Crosspoint data
The input/output number is 1:1.