Sony BKS-R1601 User Manual

Page of 158
6-6
ROUTING SWITCHER SYSTEM (E)
SONY Digital Routing System DVS-V6464B V2.10
           ITEM
    ROM CHECK SUM
8A65
    RAM READ AND WRITE
OK
    REFERENCE SIGNAL
OK
    S-BUS LINK TERMINATE
OK
    REAL TIME CLOCK
  STARTED
1993.02.03-22.15 STARTED BY DVS-V6464B Ver2.10 IN STATION 1
1993.02.03-22.15 S-BUS LINK DISCONNECTED TO CHANNEL B
1993.02.03-22.15 MISSING REFERENCE SIGNAL IN STATION 1
1993.02.03-22.15 POWER SUPPLY UNIT B DOWN IN STATION 1
1
2
3
4
5
6-6. Function Check with Control Terminal
6-6. Function Check with Control Terminal
There are two types of display modes for operation check from control terminal, which can be selected
depending upon the purpose.  The first type of display mode is provided by the system status display and
the other is provided by the “W” menu on the menu display.
The system status display shows result of self diagnostics that is performed automatically by the primary
station when the main power of the system is turned on.  It also shows error messages that are issued by
the respective stations on the S-BUS data link in real time, enabling to use the system status display as the
monitor of system operation during system run.
To check the old system status, call the menu item [W: SYSTEM STATUS LOG].
This menu takes out only the system status from the memory, and displays error messages, corresponding
station and time of occurrence.
n
As the control terminal constantly checks the errors of the system, and is capable of recording/displaying
these, it is extremely effective for monitoring the operations of the system. Therefore, it is recommended
to connect this control terminal after completing initial settings.
6-6-1. System status screen after power on
When the power of the primary station is turned on, the results of the self-diagnosis of the primary station
and the ROM checksum value, will be displayed as shown in the figure below.
If the result of the self-diagnosis is normal, “OK” will be displayed for this item. If errors have been
detected, the corresponding item will be the reversal characters.
Example of the System Status Screen After Power On
Display Contents:
1 ROM checksum value on the CPU board of the primary station.
2 Condition of the reading/writing operations of the RAM in the primary station.
3 The result of detecting the reference signal in the primary station.
4 Presence of the 75 Z termination in the S-BUS data link.
5 Oscillation of the real time clock IC.