Sony BKS-R1601 User Manual

Page of 158
7-4
ROUTING SWITCHER SYSTEM (E)
SET TIE LINES                           DVS-128  V1.00  STATION NUMBER 1
--PATHS 1------------------------------------------------------------------
SOURCE: SOURCE No.   DESTINETION No.    ROUTE:    SOURCE No.   DESTINETION No.
  L1    0001 - 0080  0001 - 0004           L2     0081 - 0082  0080 - 0086
                                      DESTINATION:SOURCE No.   DESTINETION No. 
                                           L1     0083 - 0089  0100 - 0130
--PATHS 2------------------------------------------------------------------
SOURCE:  SOURCE No.  DESTINETION No.    ROUTE:    SOURCE No.   DESTINETION No.
  L2     0001 -  0040 0005 - 0006          L.     .... - ....  .... - ....
                                      DESTINATION:SOURCE No.   DESTINETION No. 
                                           L1     0200 - 0201  0300 - 0400
--PATHS 3------------------------------------------------------------------
SOURCE:  SOURCE No.   DESTINETION No.    ROUTE:   SOURCE No.   DESTINETION No.
  L.     .... - ....  .... - ....          L.     .... - ....  .... - ....
                                      DESTINATION:SOURCE No.   DESTINETION No. 
                                           L.     .... - ....  .... - ....
--PATHS 4------------------------------------------------------------------
SOURCE:  SOURCE No.   DESTINETION No.    ROUTE:   SOURCE No.   DESTINETION No.
  L.     .... - ....  .... - ....          L.     .... - ....  .... - ....
                                      DESTINATION:SOURCE No.   DESTINETION No. 
                                           L.     .... - ....  .... - ....
F1:PgUp  F2:PgDn                                       Ctrl-E:RETURN TO MENU
7-2. Changed Menu (Primary Station Setting Items)
LEVEL TABLE                             DVS-128  V1.00    STATION NUMBER 1
                                                    LEVEL:1-16
             1=VIT   2=A1    3=A2    4=TC    5=REM   6=B32   7=....  8=....
             9=.... 10=.... 11=.... 12=.... 13=.... 14=.... 15=.... 16=....
 No. out       VIT     A1      A2      TC      REM     B32     ....    ....
 0001 OUT001   VIT     A1      ....    ....    ....    ....    ....    ....
 0002 OUT002   VIT     A1      ....    ....    ....    ....    ....    ....
 0003 OUT003   VIT     A1      A2      TC      REM     B32     ....    ....
 0004 OUT004   VIT     A1      A2      TC      REM     B32     ....    ....
 0005 OUT005   VIT     A1      A2      TC      REM     B32     ....    ....
 0006 OUT006   VIT     A1      A2      TC      REM     B32     ....    ....
 0007 OUT007   VIT     A1      A2      TC      REM     B32     ....    ....
 0008 OUT008   VIT     A1      A2      TC      REM     B32     ....    ....
 0009 OUT009   VIT     A1      A2      TC      REM     B32     ....    ....
 0010 OUT010   VIT     A1      A2      TC      REM     B32     ....    ....
 0011 OUT011   VIT     A1      A2      TC      REM     B32     ....    ....
 0012 OUT012   VIT     A1      A2      TC      REM     B32     ....    ....
 0013 OUT013   VIT     A1      A2      TC      REM     B32     ....    ....
 0014 OUT014   VIT     A1      A2      TC      REM     B32     ....    ....
 0015 OUT015   VIT     A1      A2      TC      REM     B32     ....    ....
 0016 OUT016   VIT     A1      A2      TC      REM     B32     ....    ....
 0017 OUT017   VIT     A1      A2      TC      REM     B32     ....    ....
F1:SEARCH  F2:JUMP  F3:LEVEL                     Ctrl-E:RETURN TO MENU
E : SET LEVEL TABLE
(DVS-128/HDS-X3000 Series)
Purpose
The level name can be set, and the valid level for each
output terminal can be set.
Number of levels of either 8 or 16 can also be selected.
Example of Setting Screen
Every pressing of [F3:LEVEL] toggles between the
LEVEL: 1-8 display and the LEVEL: 1-16 display on the
2 nd line.
The LEVEL 9-16 is realized by switching the Destination
to which 512 is added, at the same time.
When the system is used with the LEVEL 1-16, the remote
control panel that supports the LEVEL 1-16 becomes
necessary.
O : SET TIE LINES (DVS-128/HDS-X3000 Series)
Purpose
Change/addition/deletion of the TIE LINE data are per-
formed here.
Example of Setting Screen
To set the number, press [Enter] to be ready for number
input.  Enter a number in the range of 1 to 1024.  When
[Enter] is pressed again, the number is set, the range is
checked and duplication of the same number with other
setting is checked.  Then the number is set.
If duplication of the number is found, the entered number
becomes invalid and the former number remains as it is.
To delete a terminal number, press [Enter] without
inputting a numbers.  Then “....” appears and the terminal
number is deleted.
Number of the signals to be set is 254 at the maximum.
Number of the TIE LINEs to be set is 16 paths at the
maximum.