2-11
ROUTING SWITCHER SYSTEM (E)
SOURCE GROUPS  NET GROUPS                                DESTINATION GROUPS
S001:IN003    N001:OUT003-IN200    N002:OUT013-IN054    D001:OUT023 
     IN004         OUT004-IN201         OUT014-IN055         OUT024 
     IN005         OUT005-IN202         OUT015-IN056         OUT025
     IN006         OUT006-IN203         OUT016-IN057         OUT026 
S002:IN010    N003:OUT023-IN007    N004:OUT033-IN230    D002:OUT027 
     IN015         OUT024-IN008         OUT034-IN231         OUT028 
     IN023         OUT025-IN009         OUT035-IN233         OUT029 
     IN027         OUT026-IN010         OUT036-IN234         OUT030 
      :                             :                         :
 ( 20 groups )                 ( 40 groups )             ( 20 groups )
PATHS
  1:S001-N001-N002-D001
  2:S002-N003-D001
  3:S002-N004-D002
  :
   
( 20 paths )
2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232)
Operation example:
1.
IN023 and OUT027 are selected from the remote control unit.
2.
The CPU of the primary station detects IN023 from the source group. In the example below, the
corresponding group is S002.
3.
Like for IN023, the CPU also detects OUT027. The corresponding group is D002.
4.
The CPU of a primary station detects the path which has the S002 and D002 groups. In the following
example, the corresponding path is “3: S002-N004-D002”.
5.
As N004 will be detected as the net group to be used, the CPU selects a usable element (not protect-
ed) from the four “OUT-IN” elements set in the N004 group, and the crosspoint is switched.
In the following example, if OUT033-IN230 is usable, the path IN023
OUT033
IN230
OUT027
will be selected.
2-15.  Phantom Function
Several crosspoints can be switched simultaneously with just one push of a button of the remote control
unit. This is called the phantom function.
The phantom function is set using the control terminal connected to the primary station. The crosspoints
are switched by the remote control unit.
The group of crosspoints switched together is called the phantom group. Each remote control unit stores
the data of 57 crosspoints as the phantom group. In addition to the phantom function, in DVS-V3232B/
V6464B, BKPF-R70 or HDS-V3232, the data of 4095 crosspoints is stored in the primary station as the
other kind of phantom groups. In this manual, the registered phantoms in each remote control unit are
referred to as “local phantom”. Those registered in the primary station are referred to as “global phan-
tom”.
The global phantom function is available if a DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232 is used
as the primary station.
n
The BKS-R1607/R1608/R3209/R3210 have the local phantoms of the destination offset type in addition
to the ordinary local phantom, that support the various switching.
Refer to the operation manual supplied with equipment for more details.