Sony BKS-R1601 User Manual

Page of 158
5-8
ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
GLOBAL PHANTOM LIST            DVS-V6464B V2.10 STATION NUMBER 1
                                     (4094 REMAIN)
  No.  NAME     No.  NAME     No.  NAME     No.  NAME
  0001 GPHA001  0002 .......  0003 .......  0004 .......
  0005 .......  0006 .......  0007 .......  0008 .......
  0009 .......  0010 .......  0011 .......  0012 .......
  0013 .......  0014 .......  0015 .......  0016 .......
  0017 .......  0018 .......  0019 .......  0020 .......
  0021 .......  0022 .......  0023 .......  0024 .......
  0025 .......  0026 .......  0027 .......  0028 .......
  0029 .......  0030 .......  0031 .......  0032 .......
  0033 .......  0034 .......  0035 .......  0036 .......
  0037 .......  0038 .......  0039 .......  0040 .......
  0041 .......  0042 .......  0043 .......  0044 .......
  0045 .......  0046 .......  0047 .......  0048 .......
  0049 .......  0050 .......  0051 .......  0052 .......
  0053 .......  0054 .......  0055 .......  0056 .......
  0057 .......  0058 .......  0059 .......  0060 .......
  0061 .......  0062 .......  0063 .......  0064 .......
0=IN   1=OUT  2=.... 3=.... 4=.... 5=.... 6=.... 7=....
8=.... 9=.... A=.... B=.... C=.... D=.... E=.... F=GPHA
F1:SEARCH  F2:JUMP  F3:PgUp  F4:PgDn         Ctrl-E:RETURN TO MENU
H : SET GLOBAL PHANTOM
The phantom function switches several crosspoints
together with one button pushing of a remote control unit.
The crosspoints of different levels can be also switched
with this function.
There are two kinds of phantoms such as local phantom
and global phantom (refer to the menu item [H : SET
PHANTOM TABLE] of secondary stations for local
phantom).
In local phantom function, the phantom data is stored in a
remote control unit, and the phantom name is assigned
only on this remote control unit.   In global phantom
function, however, the phantom data is stored in the
primary station, and it can be called by any remote control
unit.  The global phantom function can be set only when
DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232 is
assigned as the primary station.
The following describes how to set the global phantom
data in the primary station.  A maximum of 4095 cross-
points can be registered.
Setting Procedure
1.
Select menu item [H].  The global phantom list will be
displayed.
2.
Select any global phantom number with the cursor or
function key and press [Enter].  The edit screen will
be displayed.
When [Ctrl] 
_ [E] is pressed, the menu screen will be
displayed.
Example of Global Phantom Screen
Operating Function Keys
(Global Phantom Display)
[F1] : SEARCH (To move the cursor to the desired global
phantom name)
1.
When [F1] is pressed, “Please Input PHAN-
TOM NAME =” will be displayed.
2.
Input the global phantom name to be retrieved.
3.
When [Enter] is pressed, the cursor will move
to the desired name.
[F2] : JUMP (To move the cursor to the desired global
 phantom number)
1.
When [F2] is pressed, “Please Input PHAN-
TOM NAME =” will be displayed.
2.
Input the global phantom to be retrieved.
3.
When [Enter] is pressed, the cursor will move
to the desired number.
[F3] : Pg Up
When [F3] is pressed, the screen will display the 16
lines previous to the 16 lines displayed currently.
[F4] : Pg Dn
When [F4] is pressed, the screen will display the 16
lines next to the 16 lines displayed currently.