Sony BKS-R1601 User Manual

Page of 158
5-14
ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
N : SET DESCRIPTION NAME GROUP
Purpose
To register the Description names required for each remote
control unit, set the group of Description names.  Up to
eight such source and destination groups can be set.
(Up to 160 names can be registered for one group.)
The top half of the screen is for setting the group and the
bottom half displays the list of Description names.
Setting Procedure
1.
Select menu item [N].
2.
Move the cursor to the group number by pressing [B].
3.
Enter the group number using the numerical keys, and
press [Enter] to set it.
4.
Press [F1] to move the cursor to the lower side of
screen.
5.
Select a number and press [Enter].  The Description
name will be copied to the space of the lowest number
on the group setting screen.
To erase the Description names on the group setting
screen, move the cursor to the number and press [BS],
[DEL] or [Ctrl] _ [P].
Example of Setting Screen
m
1.
In the remote control unit, the transferred data are all
displayed as input/output numbers.
This is because data is transferred using input/output
numbers instead of input/output names.
2.
The group data of the primary and secondary stations’
must be always the same.
If the primary station data is changed after transfer, be
sure to transfer the new data to the secondary station.
Operating Function Keys
[F1] : MOVE
(To move the cursor up and down between the
group setting screen and Description name list)
[F2] : JUMP (To move the cursor to the desired element
number)
1.
When [F2] is pressed, “Please Input ELE-
MENT NUMBER =” will be displayed.
2.
Input the element number to be retrieved.
3.
When [Enter] is pressed, the cursor will move
to the desired number.
[F3] : SOURCE (DEST.)
When [F3] is pressed, the Description name list
will be changed from destination to source.
[B] : GROUP
Press [B] to move the cursor to the group number
on the group setting screen.
[L] : COPY (To copy all data in the Description name
group to other groups)
1.
When [L] is pressed, the message “Please Input
Original Group Number  =” will be displayed
to ask for the group number to be copied.
2.
Input the group number to be copied with the
numerical keys and press [Enter].  The data of
all group will be copied to the group setting
screen currently displayed.
[S] : SEND (Transfers all data on the group setting
screen currently displayed to a secondary station)
1.
When [S] is pressed, a message “Please Input
Station Number =” will be displayed to ask for
the number of a secondary station to which the
data is to be transferred.
2.
Input the number of the secondary station using
the numerical keys and press [Enter].
All data on the group setting screen currently
displayed will be transferred to the secondary
station.
DESCRIPTION NAME GROUP          DVS-V6464B V2.10 STATION NUMBER 1
  GROUP  1  160  REMAIN
   001 .......                  002 .......
   003 .......                  004 .......
   005 .......                  006 .......
   007 .......                  008 .......
   009 .......                  010 .......
   011 .......                  012 .......
   013 .......                  014 ......
   015 .......                  016 .......
==================================================================
   001=OUT001     OUT001          002=OUT002     OUT002
   003=OUT003     OUT003          004=OUT004     OUT004
   005=OUT005     OUT005          006=OUT006     OUT006
   007=OUT007     OUT007          008=OUT008     OUT008
   009=OUT009     OUT009          010=OUT010     OUT010
   011=OUT011     OUT011          012=OUT012     OUT012
   013=OUT013     OUT013          014=OUT014     OUT014
   015=OUT015     OUT015          016=OUT016     OUT016
F1:MOVE   F2:JUMP   F3:SOURCE  B:Group  L:Copy  S:Send  Ctrl-E:RETURN TO MENU