STANDARD 
BIT RATE [BPS] 
BAUD RATE 
[BAUD] 
MODULATION CARRIER 
FREQUENCY [HZ] 
V.34bis/V.34 2400-33600  multiple 
TCM 
multiple 
V.32bis 14400  2400  128-TCM 
1800 
V.32bis 12000  2400  64-TCM 1800 
V.32bis 
7200 2400 16-TCM 
1800 
V.32  9600 2400 32-TCM 
1800 
V.32 
uncoded 
9600 2400 16-QAM 
1800 
V.32 4800 2400 4-DPSK 1800 
V.23 
1200/75 1200/75 FSK 
 
V.23  600/75 600/75 FSK   
V.22bis 2400  600 
16-QAM 1200 
Call 
2400 Ans 
V.22 
(BELL 212A) 
1200 600  4-DPSK 
1200 
Call 
2400 Ans 
V.21 300 300 FSK  
BELL 
103 
300 300 FSK  
 
3.7 Flow 
Control 
This feature refers to stopping and restarting the flow of data into and out of the modem's transmission and 
receiving data buffers. Flow control is necessary so that a device does not receive more data than it can 
handle. The Omni 56K II and Omni 56K Plus II provide two kinds of flow control methods. 
3.8  Hardware CTS/RTS Flow Control 
This is a bi-directional flow control where CTS (Clear to Send) and RTS (Ready to Send) are RS-232 signals 
that must be available on your computer. CTS is an RS-232 signal that means the device can send data now.  
RTS signifies that the device is now ready to receive data.  Both CTS and RTS are hardware methods of flow 