ZyXEL Communications omni.net LCD+M User Manual

Page of 186
Technical Reference for ZyXEL omni.net series 
 A-8 
All the Following Commands Require a 'AT' Prefix 
AT Com. 
Options 
Function & Description 
Reference 
 
I9 
Display Microsoft PnP code. 
 
 
I11 
Display PPP status. 
 
JAn 
n=0-255 
(48 *) 
Add-threshold for PPP/MP Bandwidth-On-Demand 
in Kbps unit 
S126 
JSn 
n=0-255 
(32 *) 
Sub-threshold for PPP/MP Bandwidth-On-Demand 
in Kbps unit 
S127 
KAxn 
n=0-63 
(0 *) 
Add-persist time interval for BOD; BOD disabled if n=0. 
x= M(in Minute unit) or S(in Second unit) 
S85b1-7 
KSxn 
n=0-63 
(0 *) 
Sub-persist time interval for BOD; BOD disabled if n=0. 
x= M(in Minute unit) or S(in Second unit) 
S125b1-7 
Ln 
n=0-3 
to control speaker volume 
S24b4-5 
 L0 
Low 
volume. 
 
 
L1 
Low volume. (Default.) 
 
 L2 
Medium 
volume. 
 
 L3 
High 
volume. 
 
Mn 
n=0-3 
select when the speaker will be on or off 
S21b1-2 
 
M0 
Speaker is always off. 
 
 
M1 
Speaker is on during call establishment, but off when receiving 
carrier. (Default.) 
 
 
M2 
Speaker is always on. 
 
 
M3 
Speaker on after the last digit is dialed out and off when carrier is 
detected. 
 
MW 
 
For USA NI-1 message waiting service, disable the audible & 
feature message waiting. 
 
 
Return to on-line state 
 
Pn 
n=0-6 
D-channel protocol selection (USA) for American Version 
 
 
P0   (*) 
Northern Telecom proprietary ISDN 
 
 
P1 
National ISDN 1 (1 SPID) 
 
 
P2 
National ISDN 1 (2 SPID) 
 
 P3 
Reserved