Fax Command 
All the Following Commands Require a 'AT' Prefix 
AT Com. 
Value 
Function & Description 
Reference 
+FCLASS=n 
 
Service class selection 
FAX CLASS 1 
 
n=0 
Sets to modem mode. 
 
 
n=1 
Sets to Class 1 mode 
 
+FTS=n 
0-255 
Stops transmission and pauses, in 10ms units. 
 
+FRS=n 
0-255 
Waits for silence, in 10ms units. 
 
+FTM=<MOD> 
 
Transmits data with a <MOD> carrier. 
 
+FRM=<MOD> 
 
Receives data with a <MOD> carrier. 
 
+FTH=<MOD> 
 
Transmits HDLC data with a <MOD> carrier. 
 
+FRH=<MOD> 
 
Receives HDLC data with a <MOD> carrier. 
 
Table 71a. Fax Command
The <MOD> parameter takes on the following values:  
Modulation values 
Value 
Modulation 
Speed  Requirements 
V. 21 ch. 2 
300 
Required for FTH &FRH 
24 
V. 27ter 
2400 
Required for FTH & FRH & FTM & FRM 
48 
V. 27ter 
4800 
Required for FTH & FRH & FTM & FRM 
72 
V. 29 
7200 
Required for FTH & FRH & FTM & FRM 
73 
V. 17 
7200 
Required for FTH & FRH & FTM & FRM 
74 
V. 17 w/st 
7200 
Required for FTH & FRH & FTM & FRM 
96 
V. 29 
9600 
Required for FTH & FRH & FTM & FRM 
97 
V. 17 
9600 
Required for FTH & FRH & FTM & FRM 
98 
V. 17 w/st 
9600 
Required for FTH & FRH & FTM & FRM 
121 
V. 17 
12000 
Required for FTH & FRH & FTM & FRM 
122 
V. 17w/st 
12000 
Required for FTH & FRH & FTM & FRM 
145 
V. 17 
14400 
Required for FTH & FRH & FTM & FRM 
146 
V. 17w/st 
14400 
Required for FTH & FRH & FTM & FRM 
*w/st means with V. 17 short training 
Table 71b. Modulation values