Perle Systems MDC User Manual

Page of 162
Set IOChannel
154 
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Set IOChannel Multihost
server-initiated tcp-port
The TCP Port that the channel/serial signal pin will use to communicate to another 
IOLAN or a TCP/IP application.
Default: 2000 for channel 1, then increments by one for each channel
server-initiated multihost all|backup <config_backup_host> <tcp_port>|none
Used for connections going from the Digital input channel or input serial signal pins, 
allows the input channel/serial signal pin to communicate to either all the hosts in the 
multihost list or a primary/backup host schema (see Configuring Multiple Hosts in the 
IOLAN User’s Guide  for a more detailed explanation).
local-connection <input_channel>
Specify the Digital input channel or input serial signal pin that will control the 
Digital/Relay output channel or output serial signal pin. 
Description Configures up to 49 hosts/IOLANs that the Digital input channel or input serial signal 
pins (DSR, DCD, or CTS-when the line is configured for signal-io) will connect to. To 
see a list of configured hosts/IOLANs, enter the 
show iochannel <channel>
 
command.
User Level Admin
Syntax
set iochannel <channel> multihost entry <number> delete
set iochannel <channel> multihost entry <number> host <host_name
<tcp_port>
Options
<channel>
Specify the Digital input channel or input serial signal pin that will be connecting to all 
the hosts/IOLANs in the multihost list. 
entry
Specify the multihost table entry number. Valid values are 1-49.
delete
Deletes the entry number in the multihost table.
host
Specify the preconfigured host that will be in the multihost list.
Default: None
<tcp_port>
Specify the TCP port that the I/O channel or serial signal pin will use to communicate 
to the 
Host
.
Default: 0