Delta Electronics DVP01PU-H2 Leaflet

Page of 2
1. 
 
 
Warning 
  This instruction sheet provides information on the installation, wiring and trial operation of DVP01PU-H2. For more 
detailed information, see “DVP-PLC Application Manual: Special Module”. 
  DO NOT touch any terminal when the power is switched on. Switch off the power before wiring. 
  DVP01PU-H2 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, 
humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device 
(e.g. key or specific tools are required to oepn the enclosure) in case danger and damage on the device may occur.   
  DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all 
the wiring again before switching on the power. 
 Introduction 
■■■■  Model Explanation and Peripherals 
DVP01PU-H2 pulse generation unit is mainly applied to the speed or position control of step or servo drive 
system. The maximum output pulse of DVP01PU-H2 can be up to 200kPPS. DVP01PU-H2 is built in with 
various route  control modes. Through FROM/TO instructions in DVP-EH2 MPU program, the data in 
DVP01PU-H2 can  be read or written. There are 54 16-bit control registers (CR) in DVP001PU-H2. The 
32-bit parameters are composed of 2 continuous CR#. 
■■■■  Product Profile (Indicators, Terminal Block, I/O Terminals) 
 
Unit: mm 
0
V
S
T
A
R
T
D
O
G
L
S
N
A
 -
2
4
V
S
/S
B
 -
P
G
0
-
C
L
R
-
F
P
 -
R
P
 -
S
T
O
P
L
S
P
A
 +
B
 +
P
G
0
+
C
L
R
+
F
P
+
F
P
 -
8
 
1
  DIN rail (35mm) 
6
  Terminals 
2
  Connection port for extension unit/module 
7
  Mounting hole 
3
  Model name 
8
  I/O terminals 
4
  Status indicators 
9
  Connection port for extension unit/module 
5
  DIN rail clip 
 
■■■■  LED Indicators 
POWER  : Power indicator, +5V internal power is normal 
START  : Starting input indicator 
LV 
: Low voltage indicator (on when the external 
STOP  : Stopping input indicator 
 
power supply is less than19.5V) 
DOG 
: DOG input indicator 
ERROR  : Error indicator (On/Off/flash). Flashes when 
FP 
: Forward pulse output indicator 
 
CR#44 is not 0. 
RP 
: Reverse pulse output indicator 
LSP 
: Right limit input indicator 
Φ
: MPG A-phase pulse input indicator 
LSN 
: Left limit input indicator 
Φ
: MPG A-phase pulse input indicator 
PG0 
: Zero signal input indicator 
CLR 
: Clearing signal output indicator 
■■■■  I/O Terminal Signals 
Type 
Terminal 
Description 
Response feature 
Power supply 
+24V, 0V 
Power input: 24V DC (-15 ~ +20%), Current consumption: 100mA 
START 
Starting input 
15ms/50ms 
STOP 
Stopping input 
15ms 
LSP/LSN 
Right/left limit input 
1ms 
Φ
A+, ΦA- 
MPG A-phase pulse input +, - (differential signal input) 
200kHz 
Φ
B+, ΦB- 
MPG B-phase pulse input +, - (differential signal input) 
200kHz 
Input 
PG0+, PG0-  Zero signal input +, - (differential signal input) 
1ms 
ENGLISH 
Input 
DOG 
2 variations according to different operation modes: 
1. DOG signal when in zero return 
2. Interruption signal inserted in signal-speed or 2-speed sections 
1ms 
CLR+, CLR-  Clearing signal (clearing signals in the error counter in servo drive) 
130ms 
FP+, FP- 
FP/RP mode: forward pulse output; pulse/direction: pulse output; 
A/B phase: A phase output 
200kHz 
Output 
RP+, RP- 
FP/RP mode: reverse pulse output; pulse/direction: direction output; 
A/B phase: B phase output 
200kHz 
■■■■  Wiring 
Less than
  6.8 mm
Less than
  6.8 mm
For M3.5
 
1.  Use O-type or Y-type terminals for the I/O wiring as shown in the figure. The torque of 
screw at the PLC terminal should be 5 ~ 8 kg-cm (4.3 ~ 6.9 in-lbs). 
2.  DO NOT place the wirings of input signals, output signals and power supply in the same 
wire conduit. 
3.  Use only 60/75°C copper conductors. 
■■■■  I/O Circuit 
DVP01PU-H2
START
STOP
LSP
LSN
DOG
S/S
+24V
5-24VDC
+24VDC input
24V
0V
FP+
FP-
RP+
RP-
CLR+
CLR-
A phase
ΦA+
ΦA-
ΦB+
PG0+
PG0-
5-24VDC
PLS
/PLS
SIGN
/SIGN
DI2
COM-
VDD
COM+
17
11
41
43
37
36
10
45
24V
B phase
ΦB-
Delta Servo Drive
ASDA series
Shielding cable
MPG pulse
 
 Specifications 
Item 
Description 
Power supply 
24V DC (-15% ~ +20%); Current consumption: 140 ± 30mA, supplied by DVP-EH2 MPU or 
other self-prepared power supplier 
Max. number  of 
connected modules/axes 
8 modules (axes), which will not occupy any I/O points. DVP-EH2 series MPU is able to 
connect to max. a total of 8 extension modules. 
Distance 
Set up by CR. Range: -2,147,483,648 ~ +2,147,483,647; unit: um, mdeg, 10
-4
 inch, Pulse; 
multiplications: 10
0
, 10
1
, 10
2
, 10
3
; options: absolute position or relative displacement 
Speed 
Set up by CR. Range: -2,147,483,648 ~ +2,147,483,647 (10 ~ 200kPPS pulse conversion); 
unit: pulse/s, cm/min, 10deg/min, inch/min 
External output points 
Isolated by photocoupler. LED indicators for all I/O signals. 
Output points FP and RP are differential signal (5V). 
Output point CLR is transistor NPN open collector (5 ~ 24V DC, less than 20mA). 
External input points 
Isolated by photocoupler. LED indicators for all I/O signals. 
Input points START, STOP, LSP, LSN, DOG are contacts or transistor open collector (24V DC 
± 10%, 5±1mA). 
Input points ΦA and ΦB are differential or transistor open collector (5 ~ 24V DC, 6 ~ 15mA) 
Input points PG0 is differential or transistor open collector (5 ~ 24V DC, 6 ~ 15mA) 
Pulse output methods 
In 3 modes: Pulse/Dir, FP (CW)/RP (CCW), A/B; by differential output 
Position control program 
& data exchange with 
MPU 
Through FROM/TO instructions in DVP-EH2 MPU program, DVP01PU-H2 is able to read and 
write the data in the CR. If the data are 32-bit, 2 CRs will be required to process the data. 
CR#0 ~ CR#53 are the built-in 16-bit control registers. 
When connected to 
DVP-PLC MPU in series 
The modules are numbered from 0 to 7 automatically by their distance from MPU. No. 0 is the 
closest to MPU and No. 7 is the furthest. Maximum 8 modules are allowed to connect to MPU 
and will not occupy any digital I/O points. 
■■■■  Other Specifications 
Environment 
Operation/storage 
Operation: 0°C ~ 55°C (temperature); 50 ~ 95% (humidity); pollution degree 2. 
Storage: -25°C ~ 70°C (temperature); 5 ~ 95% (humidity) 
Vibration/shock immunity 
International standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 
(TEST Ea) 
 Control Registers 
CR#   
HW 
LW 
A
d
d
re
s
s
 
L
a
tc
h
e
d
 
A
tt
ri
b
u
te
 
Content 
Setup range 
 
#0 
H’4190 
 
Model name 
Set up by the system. DVP01PU-H2 model code = H’6110 
#2 
#1 
H’4191 
 
R/W 
Number of pulses required 
for rotate motor for 1 
revolution (A) 
Range: 1 ~ +2,147,483,647 PPS/REV 
Default = 2,000 pulses/revolution (PLS/REV) 
#4 
#3 
H’4193 
 
R/W 
Distance the motor rotates 
for 1 revolution (B) 
Range: 1 ~ +2,147,483,647 unit/REV 
Default = 1,000 (unit*1/REV) 
b15  b14  b13  b12  b11  b10  b9  b8  b7  b6  b5  b4  b3  b2  b1  b0 
 
#5 
H’4195 
 
R/W 
Parameter setting 
Default = H’0000 
S
T
O
P
  in
p
u
t p
o
la
rit
y
 
S
T
A
R
T
  in
p
u
t p
o
la
rit
y
 
S
T
A
R
T
  re
s
p
o
n
s
e
 ti
m
e
 
A
c
c
e
le
ra
tio
n
 c
u
rv
e
o
p
tio
n
s
 
D
O
G
  p
o
la
rit
y
 
D
O
G
  tr
ig
g
e
r m
o
d
e
 
R
e
v
o
lu
tio
n
 d
ire
c
tio
n
 
Z
e
ro
 r
e
tu
rn
 d
ire
c
tio
n
 
L
S
N
  in
p
u
t p
o
la
rit
y
 
L
S
P
  in
p
u
t p
o
la
rit
y
 
P
u
ls
e
 o
u
tp
u
t m
e
th
o
d
s
 
M
u
lti
p
lic
a
tio
n
 o
f
 
p
o
s
iti
o
n
 d
a
ta
 
U
n
it s
e
tti
n
g
 
#7 
#6 
H’4196 
 
R/W  Maximum speed (V
MAX
Range: 0 ~ +2,147,483,647 unit*1 (10 ~ 200kPPS pulse 
conversion)*2. Default: 200,000 unit*1 
#9 
#8 
H’4198 
 
R/W  Bias speed (V
BIAS
Range: 0 ~ +2,147,483,647 unit*1 (0 ~ 200kPPS pulse 
conversion)*2. Default: 0 unit*1 
#11  #10 
H’419A 
 
R/W  JOG speed (V
JOG
Range: 0 ~ +2,147,483,647 unit*1 (10 ~ 200kPPS pulse 
conversion)*2. Default: 5,000 unit*1 
#13  #12 
H’419C 
 
R/W  Zero return speed (V
RT
Range: 0 ~ +2,147,483,647 unit*1 (10 ~ 200kPPS pulse 
conversion)*2. Default: 50,000  unit*1 
#15  #14 
H’419E 
 
R/W 
Zero return deceleration 
speed (V
CR
Range: 0 ~ +2,147,483,647 unit*1 (10 ~ 200kPPS pulse 
conversion)*2. Default: 1,000 unit*1 
 
#16 
H’41A0 
 
R/W 
The number of PG0 in 
zero return mode (N) 
Range: 0 ~ +32,767PLS 
Default: 0PLS 
 
#17 
H’41A1 
 
R/W 
The number of pulses in 
zero return mode (P) 
Range: -32,768 ~ +32,767PLS 
Default: 0PLS 
 
#18 
H’41A2 
 
R/W 
Zero return mode   
(H MODE) 
b0: zero return mode 
b1: detecting DOG falling edge in zero return mode 
#20  #19 
H’41A3 
 
R/W  Setup of zero point (HP) 
Range: 0 ~ ±999,999 unit*1. Default: 0 unit*1 
 
#21 
H’41A5 
 
R/W  Acceleration time (T
ACC
Range: 10 ~ +32,767ms. Default: 100ms 
 
#22 
H’41A6 
 
R/W  Deceleration time (T
DEC
Range: 10 ~ +32,767ms. Default: 100ms 
#24  #23 
H’41A7 
╳ 
R/W  Target position (I) (P(I)) 
Range: -2,147,483,648 ~ +2,147,483,647 unit*1 
(-2,147,483,648 ~ +2,147,483,647 pulse conversion) *2. 
Default: 0 unit*1 
#26  #25 
H’41A9 
╳ 
R/W  Operation speed (I) (V(I)) 
Range: -2,147,483,648 ~ +2,147,483,647 unit*1 (10 ~ 
200kPPS pulse conversion)*2. Default: 1,000 unit*1 
#28  #27 
H’41AB 
╳ 
R/W  Target position (II) (P(II)) 
Range: -2,147,483,648 ~ +2,147,483,647 unit*1 
(-2,147,483,648 ~ +2,147,483,647 pulse conversion)*2. 
Default: 0 unit*1 
 
CR#   
HW 
LW 
A
d
d
re
s
s
 
L
a
tc
h
e
d
 
A
tt
ri
b
u
te
 
Content 
Setup range 
#30  #29 
H’41AD 
╳ 
R/W  Operation speed (II) (V(II)) 
Range: 0 ~ +2,147,483,647 unit*1 (10 ~ 200kPPS pulse 
conversion)*2. Default: 2,000 unit*1 
b15  b14  b13  b12  b11  b10  b9  b8  b7  b6  b5  b4  b3  b2  b1  b0 
 
#31 
H’41AF 
╳ 
R/W 
Operation instruction 
Default: H’0000 
C
L
R
  o
u
tp
u
t
 
O
n
/O
ff 
C
L
R
  s
ig
n
a
l o
u
tp
u
t m
o
d
e
 
C
le
a
r C
P
 
S
o
ftw
a
re
 
S
T
A
R
T
 
A
b
s
o
lu
te
 p
o
s
iti
o
n
 s
e
tu
p
 
E
n
a
b
lin
g
 z
e
ro
 re
tu
rn
 
E
n
a
b
lin
g
 
J
O
G
 
E
n
a
b
lin
g
 
J
O
G
+
 
S
to
p
p
in
g
 re
v
e
rs
e
 p
u
ls
e
s
 
S
to
p
p
in
g
 fo
rw
a
rd
 p
u
ls
e
s
 
S
o
ftw
a
re
 
S
T
O
P
 
E
rr
o
r r
e
s
e
b15  b14  b13  b12  b11  b10  b9  b8  b7  b6  b5  b4  b3  b2  b1  b0 
 
#32 
H’41B0 
╳ 
R/W 
Work mode 
Default: H’0001 
R
e
s
t t
o
 fa
c
to
ry
 s
e
tti
n
g
 
M
A
S
K
  s
e
tti
n
g
s
 
L
S
P
/L
S
N
  s
to
p
 m
o
d
e
 
M
a
n
u
a
l P
u
ls
e
 G
e
n
e
ra
to
r
ra
n
g
e
 
S
T
O
P
  m
o
d
e
 
M
a
n
u
a
l P
u
ls
e
 G
e
n
e
ra
to
r
in
p
u
t o
p
e
ra
tio
n
 
V
a
ria
b
le
 s
p
e
e
d
 o
p
e
ra
tio
n
 
In
te
rr
u
p
tin
g
 2
-s
p
e
e
d
p
o
s
iti
o
n
in
g
 o
p
e
ra
tio
n
 
2
-s
p
e
e
d
 p
o
s
iti
o
n
in
g
o
p
e
ra
tio
n
 
In
te
rr
u
p
tin
g
 s
in
g
le
-s
p
e
e
d
p
o
s
iti
o
n
in
g
 o
p
e
ra
tio
n
 
S
in
g
le
-s
p
e
e
d
 p
o
s
iti
o
n
in
g
o
p
e
ra
tio
n
 
#34  #33 
H’41B1 
╳ 
R/W  Current position CP (PLS) 
Range: -2,147,483,648 ~ +2,147,483,647PLS. 
Default: 0PLS   
#36  #35 
H’41B3 
╳ 
R/W  Current speed CS (PPS) 
Range: 0 ~ +2,147,483,647PPS.Default: 0PPS 
#38  #37 
H’41B5 
╳ 
R/W 
Current position CP 
(unit*1) 
Range: -2,147,483,648~+2,147,483,647 unit*1 
Default: 0 unit*1
 
#40  #39 
H’41B7 
╳ 
R/W  Current speed CS (unit*1)  Range: 0 ~ +2,147,483,647 unit*
1
. Default: 0 unit*1 
 
#41 
H’41B9  ○
 
R/W 
Communica- 
tion address setting 
Setting up RS-485 communication address. Range: 01 ~ 
254. 
Default: K1 
 
#42 
H’41BA  ○
 
R/W 
Communication speed 
(baud rate) setting 
For setting up communication speed: 
4,800/9,600/19,200/38,400/ 57,600/115,200bps.ASCII data 
format: 7-bit, even bit, 1 stop bit (7, E, 1). RTU data format: 
8-bit, even bit, 1 stop bit (8, E, 1).   
b0: 4,800bps. b1: 9,600 bps (Default). 
b2: 19,200bps. b3: 38,400bps. b4: 57,600bps. b5: 
115,200bps 
b6  ~  b14:  reserved.  b15:  0=RTU  mode;  1=ASCII  mode 
(Default). 
b15  b14  b13  b12  b11  b10  b9  b8  b7  b6  b5  b4  b3  b2  b1  b0 
 
#43 
H’41BB 
╳ 
R/W 
Execution  status 
Default: H’XXXX 
M
P
G
 in
p
u
t c
o
u
n
tin
g
 d
o
w
n
 
M
P
G
 in
p
u
t c
o
u
n
tin
g
 u
p
 
R
o
u
te
 p
a
u
s
e
s
 
P
o
s
iti
o
n
in
g
 is
 c
o
m
p
le
te
d
 
E
rr
o
r o
c
c
u
rr
e
d
 
C
P
  v
a
lu
e
 o
v
e
rfl
o
w
s
 
Z
e
ro
 re
tu
rn
 is
 c
o
m
p
le
te
d
 
R
e
v
e
rs
e
 p
u
ls
e
 o
u
tp
u
t i
n
p
ro
g
re
s
s
 
F
o
rw
a
rd
 p
u
ls
e
 o
u
tp
u
t  in
p
ro
g
re
s
s
 
E
x
e
c
u
tio
n
 s
ta
tu
s
 
 
#44 
H’41BC 
╳ 
Error code 
See “
 Error Code & Troubleshooting” Default: H’0000 
 
#45 
H’41BD 
╳ 
R/W 
Numerator of MFG 
electronic gearing 
See explanations below. Default: H’1. 
 
#46 
H’41BE 
╳ 
R/W 
Denominator of MFG 
electronic gearing 
See explanations below. Default: H’1. 
#48  #47 
H’41BF 
╳ 
R/W  Input frequency of MPG 
Input pulse frequency. Default: 0. 
#50  #49 
H’41C1 
╳ 
R/W 
Accumulated number of 
pulses by MPG 
Accumulated by the number of pulse input from MPG. 
Forward pulse is accumulated by “plus” and reverse pulse 
is accumulated by “minus”. The accumulated value will not 
be affected by the settings in CR#45 and CR#46. Default: 
0. 
Set  value 
Response 
speed 
5
≧  
4ms (default) 
32ms 
108ms 
256ms 
 
#51 
H’41C3 
╳ 
R/W 
Response speed of MPG 
input 
1 or 0 
500ms 
The faster the response speed, 
the more synchronous the 
instruction pulse output and 
MPG pulse input. The slower the 
response speed, the more 
possible the instruction pulse 
output lags behind MPG pulse 
input. (Default: 5) 
bit # 
Status 
Description 
b0 
START input 
When START input is On, b0=On. 
b1 
STOP input 
When STOP input is On, b1=On. 
b2 
DOG input 
When DOG input is On, b2=On. 
b3 
PG0 input 
When PG0 input is On, b3=On. 
b4 
LSP input 
When LSP input is On, b4=On. 
b5 
LSN input 
When LSN input is On, b5=On. 
b6 
A phase input 
When A phase input is On, 
b6=On. 
b7 
B phase input 
When B phase input is On, 
b7=On. 
 
#52 
H’41C4 
╳ 
Terminal status 
b8 
CLR output 
When CLR output is On, b8=On. 
 
#53 
H’41C5 
○ 
Firmware version 
Displayed in hex; e.g. V1.00 is indicated as H’0100. 
*1: The setting of unit is in accordance with b0 and b1 of CR#5. 
*2: The module outputs the maximum pulses if the pulse conversion value exceeds the range and outputs the minimum pulses if the 
conversion value falls below the range. 
CR#0 ~ CR#53: The  corresponding  parameter  addresses H’4190 ~ H’41C5 are for users to read/write data by 
RS-485 communication. When using RS-485, th e user has to separate the module with MPU first.   
a. Communication baud  rate: 4,800/9,600/19,200/38,400/57,600/115,200bps 
b. Modbus ASCII/RTU  communication  protocols: ASCII data format (7-bit, even bit, 1 stop bit (7, E, 1)); RTU 
data format (8-bit, even bit, 1 stop bit (8, E, 1)). 
c. Function: H’03 (read register data); H’06 (write 1 word datum to register); H’10 (write many word data to 
register) 
d. Latched CR should be written by RS-485 communication to stay latched. CR will not be latched if written 
by MPU through TO/DTO instruction.   
 Error Code & Troubleshooting 
ERROR LED will be on when hardware malfunction or incorrect parameter settings occur. The error code will 
be recorded in CR#44. 
Error code 
Explanation 
Error code 
Explanation 
H’0000 
No error 
H’0014 
Incorrect V
JOG
 
H’0001 
Incorrect target position (I) 
H’0020 
FP is forbidden 
H’0002 
Incorrect target position (II) 
H’0021 
RP is forbidden 
H’0010 
Incorrect operation speed (I) 
H’0030 
Low voltage 
H’0011 
Incorrect operation speed (II) 
H’0080 
Hardware error in internal memory 
H’0012 
Incorrect V
CR
 
H’0081 
Incorrect written in data in internal memory 
H’0013 
Incorrect V
RT
 
 
 
 
 
注意事項 
  本手冊主要提供 DVP01PU-H2 定位模組安裝、配線回路及試機之參考,有關進一步的使用說明,請參考
DVP-PLC
應用技術手冊【特殊模組篇】。 
  請勿在上電時觸摸任何端子。實施配線,務必關閉電源。 
  本機為開放型
 
(Open Type)
 
機殼,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊/衝擊意
外之外殼配線箱內。另必須具備保護措施(如:特殊之工具或鑰匙才可打開)防止非維護人員操作或意外衝
擊本體,造成危險及損壞。 
  交流輸入電源不可連接於輸入
出信號端,否則將造成嚴重的損壞,請在上電之前再次確認電源配線。 
 
產品簡介 
 
    說明及週邊裝置    
DVP01PU-H2
脈波產生單元主要可應用於步進或伺服驅動系統之速度或位置控制,最高 200kPPS 脈波輸出,
內建多種行程控制模式。透過 DVP-PLC EH2 系列主機程式以指令 FROM/TO 來讀寫模組內之資料,模組內具
有 54 個 CR 暫存器,每個暫存器為 16 bits。32 位元數值參數由兩個連續編號的 CR 所組成。 
  產品外觀  (指示燈、端子台、端子配置) 
 
尺寸單位:mm 
0
V
S
T
A
R
T
D
O
G
L
S
N
A
 -
2
4V
S
/S
B
 -
P
G
0
-
C
L
R
-
F
P
 -
R
P
 -
S
T
O
P
L
S
P
A
 +
B
 +
P
G
0
+
C
L
R
+
F
P
+
F
P
 -
8
 
1
  DIN 軌糟  (35mm) 
6
  端子 
2
  擴充機/擴充模組連接口 
7
  固定孔 
3
  機種名稱 
8
  端子配置 
4
  電源、錯誤及轉換指示燈 
9
  擴充機/擴充模組連接座 
5
  DIN 軌固定扣 
 
  面板指示燈 
POWER 
:電源指示燈,內部+5V 電源正常 
START 
:啟動輸入指示燈 
LV 
:低電壓指示燈,外部電源輸入小於 
STOP 
:停止輸入指示燈 
 
19.5V
,該指示燈亮 
DOG 
:近點信號輸入指示燈 
ERROR 
:錯誤指示燈  (On/Off 閃爍),當 CR#44   
FP 
:正轉方向脈波輸出指示燈 
 
錯誤編號不為零時動作 
RP 
:反轉方向脈波輸出指示燈 
LSP 
:右極限輸入指示燈 
ΦA 
:手搖輪 A 相脈波輸入指示燈 
LSN 
:左極限輸入指示燈 
ΦB 
:手搖輪 B 相脈波輸入指示燈 
PG0 
:零點訊號輸入指示燈 
CLR 
:清除信號輸出指示燈 
 
繁體中文 
  輸入輸出端子信號 
種類 
端子 
說明 
響應特性 
電源輸入供應  +24V, 0V, 
輸入電源,24V DC (-15 ~ +20%),消耗電流 100mA 
START 
啟動輸入 
15ms/50ms 
STOP 
停止輸入 
15ms 
LSP/LSN 
右極限輸入左極限輸入 
1ms 
ΦA+, ΦA- 
手搖輪 A 相脈波輸入+, -(差動信號輸入) 
200kHz 
ΦB+, ΦB- 
手搖輪 B 相脈波輸入+, -(差動信號輸入) 
200kHz 
PG0+, PG0- 
零點訊號輸入+, -(差動信號輸入) 
1ms 
輸入 
DOG 
依照運轉模式不同有下列 2 種變化: 
1.
原點復歸時為近點信號;2.一段速或二段速插入啟動信號 
1ms 
CLR+, CLR- 
清除信號(Servo 驅動器內部偏差計數器清除信號) 
130ms 
FP+, FP- 
正/反轉模式:正轉方向脈波輸出;脈波/方向:脈波輸出端; 
AB
相模式:A 相輸出 
200kHz 
輸出 
RP+, RP- 
正/反轉模式:反轉方向脈波輸出;脈波/方向:方向輸出端; 
AB
相模式:B 相輸出 
200kHz 
  配線 
 
6.8 mm 
以下
6.8 mm 
以下
M3.5  用
使
 
1. 
輸出/入配線端請使用 O 型或 Y 型端子,端子規格如左所示。PLC 端子鏍絲扭力為 5 ~ 8 kg-cm 
(4.3 ~ 6.9 in-lbs)
。 
2. 
在配線時請勿請輸入點信號線與輸出點或電源等動力線置於同一線糟內。 
3. 
只能使用 60/75°C 的銅導線 
  輸入
輸出回路配線 
DV P 01PU- H2
S TA RT
STO P
LS P
LS N
DO G
S/ S
+24 V
5-24 V DC
+24 V DC
輸入
24V
0V
FP +
F P-
RP +
RP -
CL R+
CLR -
台達伺服驅動器
隔離 線
手搖輪脈波
相 
ΦA+
ΦA-
ΦB+
PG0 +
PG0 -
5- 24VD C
PL S
/PL S
SIG N
/SIG N
DI 2
COM -
ASDA 列
VD D
COM +
17
11
41
43
37
36
10
45
24V
ΦB-
 
 
規格 
項目 
說明 
電源輸入 
24V DC (-15% ~  +20%) 
消耗電流 140±30mA;可由 DVP-EH2 主機取得或自備電源供應器。 
最大連接台(軸)數 
8
台(軸);(不佔任何 I/O 點數,DVP-EH2 主機所能連接特殊擴充機台數總和為 8 台) 
距離值 
距離設定值由控制暫存器來設定 
1. 
設定值:-2,147,483,648 ~ +2,147,483,647;2.  單位可選擇:um, mdeg, 10
 -4
 inch, Pulse
; 
3. 
可選擇倍率:10
 0
, 10
 1
, 10
 2
, 10
 3
;4.  可選擇絕對位置或相對移動量 
速度值 
速度設定值由控制暫存器來設定 
 
1. 
設定值:-2,147,483,648 ~ +2,147,483,647 (10 ~ 200kPPS 的脈波轉換值); 
2. 
單位可選擇:pulse/s, cm/min, 10deg/min, inch/min