DELL 9.7(0.0) User Manual

Page of 1039
Examples of Running Offline Diagnostics
Example of Taking a Switch Offline
Dell# offline system 
Warning - offline of system will bring down all the protocols and
the system will be operationally down, except for running Diagnostics.
The "reload" command is required for normal operation after the offline command 
is issued.
Proceed with Offline [confirm yes/no]:yes
00:10:29: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 0 down - linecard offline
FTOS-BMP#00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to 
down: Fo 0/4
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 0/0-44,
00:10:30: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 1 down - linecard offline
00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/0
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 1/0-44,
00:10:30: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: linecard 2 down - linecard offline
00:10:30: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 2/0
00:10:30: %SYSTEM:CP %IFMGR-1-DEL_PORT: Removed port: Fo 2/0-44,
00:10:31: %SYSTEM:CP %CHMGR-2-UNIT_DOWN: CP unit down - CP unit offline
Example of Verifying the Offline/Online Status of a Switch
Dell# show system brief
System MAC : 74:86:7a:ff:70:74
Reload-Type                :   normal-reload [Next boot : normal-reload]
--  Linecard Info  --
LinecardId     Type    Status     ReqTyp       CurTyp      Version    Ports
---------------------------------------------------------------------------
       0   Linecard    offline    Z9500LC36    Z9500LC36   9.2(1.0B2)  144
       1   Linecard    offline    Z9500LC48    Z9500LC48   9.2(1.0B2)  192
       2   Linecard    offline    Z9500LC48    Z9500LC48   9.2(1.0B2)  192
--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)   Power Usage (W)
-----------------------------------------------------------------------------
  0     0    up           AC      up          19264            290.0
  0     1    up           AC      up          19104            288.5
  0     2    up           AC      up          19072            288.5
  0     3    up           AC      up          19328            324.0
Total power:  1191.0 W
--  Fan  Status  --
Unit   Bay   TrayStatus  Fan0    Speed   Fan1    Speed
------------------------------------------------------
  0     0     up          up      6581    up      6614
  0     1     up          up      6542    up      6603
  0     2     up          up      6548    up      6704
  0     3     up          up      6642    up      6619
  0     4     up          up      6581    up      6642
Speed in RPM
Example of Running Offline Diagnostics on a Standalone Switch
Dell# diag system unit
Warning - diagnostic execution will cause multiple link flaps on the peer side 
- advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
FTOS-BMP#00:11:05: %Z9500LC12:1 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on 
linecard 1
Debugging and Diagnostics