Avocent EMS1000P User Manual

Page of 41
16
Emerge EMS Installer/User Guide
 
Chapter 2: Installation
17
Making Cascade Connections
The Emerge EMS series of products have been specifically designed to be flexible in order to 
support both your immediate and future needs for media streaming. In addition to the standard 
connections made from transmitters to receivers, you can also link extra transmitters to 
transmitters and/or receivers to receivers in order to provide more display/speaker outputs. These 
non-standard links are called cascade connections
Important Limitations When Cascading Emerge EMS units
•  There should never be more than three cascade connections between the Primary Transmitter 
(the one connected to the source PC) and any receiver. The cascade connections can all occur 
at the transmitter end or all at the receiver end (EMS1000MP-R only) or at a mixture of both. 
•  Each cascade connection reduces the overall link length permissible from a transmitter to the 
final receiver in a branch. To calculate the recommended overall maximum link length for a 
branch, count the number of cascade connections between the Primary Transmitter and the 
final receiver in that branch. The effects of cascade connections on overall branch link lengths 
are as follows:
Table 2.1: How cascade connections affect overall maximum link cable lengths (EMS1000MP)
Number of cascade connections 
Overall length of links for the branch
(in a branch) 
(from transmitter to furthest receiver)
1000 feet (300m)
800 feet (250m)
650 feet (200m)
600 feet (175m)
Notes
EMS1000P models should always be limited to link lengths of 600 feet or less, regardless of 
cascade connections, due to a lack of skew compensation adjustments.
The lengths of transmitter cascade connections should never be longer than 6 feet (2m) and can be 
considered to have a negligible effect upon overall link lengths.
The maximum resolutions achievable are: 1600 x 1200 x 60 Hz at 200m and 1280 x 1024 x 60Hz 
at 300m. If you are using lower resolutions then it may be possible to achieve longer transmission 
distances than shown in the above table although we do not recommend runs longer than 1000ft 
in any installation. If you are running shorter cables then it may be possible to use more cascades 
than shown in the above table.