Datalogic Scanning Matrix-1000 User Manual

Page of 67
Matrix-1000™ Reference Manual 
 
Matrix-1000
™ is able to decode code labels at a variety of angles, however significant 
angular distortion may degrade reading performance. 
 
When mounting Matrix-1000
™, take into consideration these ideal label position angles: 
Pitch 10° to 20° and Tilt 0°
 
Note: Since Matrix-1000
™ is omni-directional on the code plane, the Pitch and Skew angles 
have the same significance with respect to the code plane. However in some advanced code 
reading applications performance can be improved by modifying the Skew angle. 
 
Follow the suggestions below for the best orientation: 
 
The Pitch and Skew angles are represented by the values P and S in Figure 33 and in Figure 
34. 
Position the reader in order to avoid the direct reflection of the light emitted by the Matrix-
1000
™ reader; it is advised to assure at least 10° for one of these angles. In some cases, 
such as low contrast or low illumination, it can be useful to use a Pitch or Skew angle = 0°. 
 
 
Figure 33 - Pitch angle 
 
 
 
Figure 34 - Skew angle 
 
 
The Tilt angle is represented by the value T in Figure 35. Matrix-1000
™ can read labels with 
any tilt angle. 
 
 
Figure 35 - Tilt angle 
32