Panasonic MA4X713 (MA713) User Manual

Page of 3
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004
SKH00103BED
MA4X713 
(MA713)
Silicon epitaxial planar type
For switching
For wave detection
■ Features
• Two isolated elements are contained in one package, allowing
high-density mounting
• Two MA3X704A (MA704A) is contained in one package (of a
type in the same direction)
• Forward voltage V
F
 , optimum for low voltage rectification
• Optimum for high frequency rectification because of its short
reverse recovery time t
rr
■ Absolute Maximum Ratings  T
a
 
= 25°C
Parameter
Symbol
Rating
Unit
Reverse voltage
V
R
30
V
Maximum peak reverse voltage
V
RM
30
V
Peak forward
Single
I
FM
150
mA
current
Double 
*
110
Forward current
Single
I
F
30
mA
Double 
*
20
Junction temperature
T
j
125
°C
Storage temperature
T
stg
−55 to +125
°C
Internal Connection
Marking Symbol: M1N
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Forward voltage
V
F1
I
F
 
= 1 mA
0.4
V
V
F2
I
F
 
= 30 mA
1.0
Reverse current
I
R
V
R
 
= 30 V
1
µA
Terminal capacitance
C
t
V
R
 
= 1 V, f = 1 MHz
1.5
pF
Reverse recovery time 
*
t
rr
I
F
 
= I
R
 
= 10 mA
1.0
ns
I
rr
 
= 1 mA, R
L
 
= 100 Ω
Detection efficiency
η
V
in
 
= 3 V
(peak)
 , f 
= 30 MHz
65
%
R
L
 
= 3.9 kΩ, C
L
 
= 10 pF
■ Electrical Characteristics  T
a
 
= 25°C ± 3°C
4
1
3
2
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
 = 50 Ω
Wave Form Analyzer
(SAS-8130)
R
i
 = 50 Ω
t
p
 = 2 µs
t
r
 = 0.35 ns
δ = 0.05
I
F
 = 10 mA
I
R
 = 10 mA
R
L
 = 100 Ω
10%
Input Pulse
Output Pulse
I
rr
 = 1 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1: Cathode 1
2: Cathode 2
3: Anode 2
4: Anode 1
EIAJ: SC-61
Mini4-G1 Package
2.90
+0.02
–0.05
0.16
+0.1
–0.06
0.4
±
0.2
10˚
0.60
+0.10
–0.05
1.1
+0.2 –0.1
1.1
+0.3 –0.1
1.50
+0.25 –0.05
2.8
+0.2 –0.3
1.9
±0.2
(0.65)
(0.2)
(0.95)
(0.95)
0 to 0.1
3
4
2
1
0.5R
Note) *: Value of each diode in double diodes used.
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 2 GHz.
4. *: t
rr
 measurement circuit
Note) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).