Compaq EV67 User Manual

Page of 356
Alpha 21264/EV67 Hardware Reference Manual
Thermal Management
10–1
 10
Thermal Management
This chapter describes the 21264/EV67 thermal management and thermal design 
considerations, and is organized as follows:
Operating temperature
Heat sink specifications
Thermal design considerations
10.1 Operating Temperature
The 21264/EV67 is specified to operate when the temperature at the center of the heat 
sink (T
c)
 is as shown in Table 10–1. Temperature T
c
 should be measured at the center of 
the heat sink, between the two package studs. The GRAFOIL pad is the interface mate-
rial between the package and the heat sink.
Note:
Compaq recommends using the heat sink because it greatly improves the 
ambient temperature requirement.
Table 10–1 Operating Temperature at Heat Sink Center 
(T
c
)
T
Frequency
80.2
° 
C
600 MHz
78.1
° 
C
667 MHz
76.9
° 
C
700 MHz
76.0
° 
C
733 MHz
75.4
° 
C
750 MHz
72.7
° 
C
833 MHz