Thermal Management
10–7
Thermal Design Considerations
10.3 Thermal Design Considerations
Follow these guidelines for printed circuit board (PCB) component placement:
Orient the 21264/EV67 on the PCB with the heat sink fins aligned with the airflow 
direction.
Avoid preheating ambient air. Place the 21264/EV67 on the PCB so that inlet air is 
not preheated by any other PCB components.
Do not place other high power devices in the vicinity of the 21264/EV67.
Do not restrict the airflow across the 21264/EV67 heat sink. Placement of other devices 
must allow for maximum system airflow in order to maximize the performance of the 
heat sink.