ZyXEL Communications IES-612-51A User Manual

Page of 444
Chapter 35 Static Routing
IES-612-51A User’s Guide
236
Metric
The metric represents the “cost” of transmission for routing purposes. IP routing 
uses hop count as the measurement of cost, with a minimum of 1 for directly 
connected networks. Enter a number that approximates the cost for this link. 
The number need not be precise, but it must be between 1 and 15. In practice, 2 
or 3 is usually a good number.
Add
Click Add to save the new rule to the IES-612-51A’s volatile memory. It then 
displays in the summary table at the bottom of the screen. The IES-612-51A 
loses these changes if it is turned off or loses power, so use the Config Save 
link on the navigation panel to save your changes to the non-volatile memory 
when you are done configuring.
Cancel
Click Cancel to reset the fields to your previous configuration.
Use this section to look at a summary of all static routes in the IES-612-51A.
Previous Page
Click this to display the preceding page of static route entries. 
Next Page
Click this to display the following page of static route entries.
Index
This field displays the index number of the route. 
Name
This field displays the name of this static route.
Destination Address
This field displays the IP network address of the final destination. 
Subnet Mask
This field displays the subnet mask for this destination.
Gateway Address
This field displays the IP address of the gateway. The gateway is an immediate 
neighbor of your device that will forward the packet to the destination. 
Metric
This field displays the cost of transmission for routing purposes.
Delete
Select the rule(s) that you want to remove in the Delete column, and then click 
the Delete button.
Cancel
Click Cancel to clear the selected check boxes in the Delete column.
Table 79   Static Routing (continued)
LABEL
DESCRIPTION