For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system.  Never operate heater if
ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that
could result in injury or death.  Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness,
or nausea.  If you develop these symptoms GET FRESH AIR AT ONCE.  Turn off heater and call a qualified serviceman to
check heater.  Some people are more affected by Carbon Monoxide than others:  Including pregnant women, persons with
a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.
OPERATION
Infrared heaters “heat like the sun” with almost instantaneous, safe, clean burning “waves” of infrared heat.  Like the sun,
they must “see” the object to be heated.  Make sure they are installed away from furniture or any other object which
might block the infrared “waves”.  The Cozy thermostatically controlled units offer the additional benefit of automatically
cycling the heating to maintain just the right room temperature.  Ventfree gas room heaters are designed strictly for
“supplemental” room heat use and should never be installed as “sole source heating”.
ROOM HEATER SPECIFICATIONS
Your room heater comes packed in a single carton.  Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.
SAFETY INSTRUCTIONS
1)
Keep burner and control compartment clean.
2)
Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.
3)
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns
or clothing ignition.
4)
Young children should be carefully supervised then they are in the same room with this heater.
5)
Do not place clothing or other flammable material on or near the heater.
6)
Any safety screen or guard removed for servicing must be replaced prior to operating the heater.
Page 3
MODEL NUMBER
                           MANUAL MODELS
      THERMOSTAT MODELS
NATURAL GAS
VFM63
VFM103
VFM203
VFM303
VFT101
VFT201
VFT301
PROPANE GAS
VFM64
VFM104
VFM204
VFM304
VFT102
VFT202
VFT302
TYPE CONTROL
MAN.
MAN.
MAN.
MAN.
T-STAT
T-STAT
T-STAT
BULB
BULB
BULB
HEIGHT
22-1/2”
22-1/2”
22-1/2”
22-1/2”
22-1/2”
22-1/2”
22-1/2”
WIDTH
11-1/2”
14-9/16”
20-11/16”
26-13/16”
14-9/16”
20-11/16”
26-13/16”
DEPTH
7 ”
7 ”
7 ”
7 ”
7 ”
7 ”
7 ”
INPUT (BTU/HR.)
5,500
10,000
LO / 10,000
LO / 10,000
10,000
20,000
30,000
HI / 20,000
MED./20,000
HI / 30,000
Gas Supply Line Size
½”
½”
½”
½”
½”
½”
½”
Optional CVF Blower
NO
NO
YES
YES
NO
YES
YES
Optional Floor Stand
NO
YES
YES
YES
YES
YES
YES
Bathroom Installation
YES
NO
NO
NO
NO
NO
NO
Bedroom Installation
YES
YES
NO
NO
YES
NO
NO
Piezo Ignitor
YES
YES
YES
YES
YES
YES
YES
Shipping Weight
16 LB.
22 LB.
30 LB.
35 LB.
22 LB.
30 LB.
35 LB.
As applicable:
1.  An unvented room hetaer having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom
     or bathroom; or
2.  An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.