Lennox Hearth EDVSTNM-B User Manual

Page of 44
3
       WARNING 
Improper  installation,  adjust-
ment,  alteration,  service  or 
maintenance  can  cause  injury 
or  property  damage.    Refer  to 
this manual.  For assistance or 
additional  information  consult 
a  qualified  installer,  service 
agency or the gas supplier.
       WARNING 
Failure  to  comply  with  these 
installation instructions will result 
in  an  improperly  installed  and 
operating appliance, voiding its 
warranty.  Any change to this appli-
ance and/or its operating controls 
is dangerous.
       WARNING 
Clothing  or  other  flammable 
material  should  not  be  placed 
on or near the appliance.
       AVERTISSEMENT 
On  ne  devrait  pas  placer  de 
vêtements  ni  d’autres  matières 
inflammables sur l’appareil ni à 
proximité.
       WARNING 
Any  safety  screen  or  guard 
removed for servicing the appli-
ance must be replaced prior to 
operating the appliance.
       AVERTISSEMENT 
Tout écran ou protecteur retiré 
pour  permettre  l’entretien  de 
l’appareil  doit  être  remis  en 
place avant de mettre l’appareil 
en marche.
Note: Installation and repair should be done 
by a qualified service person. The appliance 
should be inspected before use and at least 
annually by a professional service person. 
More  frequent  cleaning  may  be  required 
due  to  excessive  lint  from  carpeting,  bed-
ding  material,  etcetera.  It  is  imperative 
that  control  compartments,  burners  and 
circulating air passageways of the appliance 
be kept clean.
Remarque:  L’installation  et  la  réparation 
devrait être confiées à un technicien qualifié. 
L’appareil devrait faire l’objet d’une inspection 
par un technicien professionnel avant d’être 
utilisé et au moins une fois l’an par la suite. 
Des nettoyages plus fréquents peuvent être 
nécessaires si les tapis, la literie, et cetera 
produisent une quantité importante de pous-
sière. Il est essentiel que les compartiments 
abritant les commandes, les brûleurs et les 
conduits  de  circulation  d’air  de  l’appareil 
soient tenus propres.
Do  not  use  these  appliances  if  any  part 
has been under water.  Immediately call a 
qualified, professional service technician 
to inspect the appliance and to replace any 
parts  of  the  control  system  and  any  gas 
control which have been under water.
Ne pas utiliser cet appareil s’il a été plongé, 
même  partiellement,  dans  l’eau.  Ap-
peler un technicien qualifié pour inspecter 
l’appareil  et  remplacer  toute  partie  du 
système de commande et toute commande 
qui a été plongée dans l’eau.
Misc. Codes / Standards -
The Installation must conform to local codes or, 
in the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 
edition (In Canada, the current CAN/CSA-B149.1 
installation code).
The appliance, when installed, must be electri-
cally grounded and wired in accordance with 
local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 
70 - latest edition, or the Canadian Electrical 
Code, CSA C22.1 - latest edition
.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct the 
front or  back openings of the appliance.
These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels  or  combination  of  fuels  will  degrade 
the performance of this system and may be 
dangerous.
These fireplaces are designed as supplemental 
heaters.  Therefore,  it  is  advisable  to  have  an 
alternate  primary  heat  source  when  installed 
in a dwelling.
Millivolt Models - The millivolt appliances are 
manually controlled and feature a spark igniter 
(piezo) that allows the appliance's pilot gas to 
be lit without the use of matches or batteries.  
This system provides continued service in the 
event of a power outage.
Millivolt models come standard with a manually-
modulated  gas  valve;  flame  appearance  and 
heat output can be controlled at the gas valve. 
The BTU Input for these appliances is shown 
in Table 1.
Electronic Models - Electronic models have a 
fixed rate gas valve.  Input of electronic models 
is shown in Table 1.
 Input (BTU) Gas Valves (all models)
All Models
Fuel 
Type
Input Rate
(BTU / HR)
Millivolt
Natural
39,000 high
31,000 low
Millivolt
Propane 39,000 high
31,000 low
Electronic
Natural
39,000
Electronic
Propane
39,000
Table 1
Only trim kit(s) supplied by the manufacturer 
shall be used in the installation of this ap-
pliance.
Seules  les  trousses  de  garniture  fournies 
par le fabricant doivent être utilisées pour 
l’installation de cet appareil.
These appliances comply with National Safety 
Standards and are tested and listed by OMNI-Test 
Laboratories, Inc.  (Report No. 116-F-04-5) to 
ANSI Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91  in  both  USA  and  Canada,  as 
vented gas fireplace heaters.
Both  millivolt  and  electronic  versions  of 
these  appliances are listed by OMNI-Test 
Laboratories  for  installation  in  bedrooms 
and Manufactured Homes. 
       WARNING 
Improper installation or use of 
this appliance can cause serious 
injury or death from fire, burns, 
explosions or carbon monoxide 
poisoning.