P36 - P36D  Zero Clearance Direct Vent Gas Fireplace
Model
P36-NG4
P36-LP4
P36D-NG1
P36D-LP1
Fuel Type
Natural Gas
Propane
Natural Gas
Propane
Minimum Supply 
Pressure
5” W.C. 
(1.25 kPa)
12” W.C. 
(3.00 kPa)
5” W.C. 
(1.25 kPa)
12” W.C. 
(3.00 kPa)
Manifold 
Pressure - High
3.8” W.C. 
(0.95 kPa)
11” W.C. 
(2.74 kPa)
3.8” W.C. 
(0.95 kPa)
11” W.C. 
(2.74 kPa)
Manifold 
Pressure - Low
1.1” W.C. 
(0.27 kPa)
2.9” W.C. 
(0.72 kPa)
1.1” W.C. 
(0.27 kPa)
2.9” W.C. 
(0.72 kPa)
Orifi ce Size
#37 DMS
#52 DMS
#37 DMS
#52 DMS
Minimum Input 
15,500 BTU/h 
(4.54 kW) 
15,000 BTU/h 
(3.96 kW) 
15,500 BTU/h 
(4.54 kW) 
15,000 BTU/h 
(3.96 kW) 
Maximum Input
30,000 BTU/h 
(8.79 kW) 
30,000 BTU/h 
(8.79 kW) 
30,000 BTU/h 
(8.79 kW) 
30,000 BTU/h 
(8.79 kW) 
Vent Sizing
4” Inner / 6 5/8” 
Outer
4” Inner / 6 5/8” 
Outer
4” Inner / 6 5/8” 
Outer
4” Inner / 6 5/8” 
Outer
A
D
C
F
E
A
B
Unit Dimensions
Description
P36
P36D
A
Front Face Width
36” (914mm)
36” (914mm)
B
Rear Firebox Width
33-1/4” (838mm)
33-1/4” (838mm)
C
Front Face Height
30-1/2” (775mm)
30-1/2” (775mm)
D
Height w/ Standoff
36” (914mm)
37” (940mm)
E
Unit Depth
12-3/4” (324mm)
17-1/8” (435mm)
F
Height to Vent
32-1/2” (826mm)
32-1/2” (826mm)
Framing Dimensions
Description
P36
P36D
G
Framing Width*
36-1/4” (921mm)
36-1/4” (921mm)
H
***
Framing Height*  
***
36-1/4” (921mm)
***
37-1/4” (946mm)
***
I
Framing Depth*
12-3/4” (324mm)
17-1/8” (435mm)
J
Corner Wall Length
42-7/16” (1078mm)
48” (1219mm)
K
C o r n e r   F a c i n g   Wa l l 
Width
60” (1524mm)
68” (1727mm)
L
Framed Chase Ceiling
46” (1168mm)
46-1/2” (1181mm)
M
Vent Centerline Height
40-1/2” (1029mm)
40-1/2” (1029mm)
N
Gas Connection Height
2” (51mm)
2” (51mm)
O
Gas Connection Inset
3-1/2” (89mm)
3-1/2” (89mm)
P
Gas Connection Width
4” (102mm) 
4” (102mm) 
G
H
I
K
J
L
O P
N
M
10" (254mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
Drywall
(or other
facing)
*
If using the Barcelona Surround, Kensington, Balmoral, or 
Tripoli Screen Door  please note that framing and facing must 
be non combustible (12” on top and 6” on both sides) and  that 
the Barcelona is only approved  for installation with a single 
sidewall.
P36 - P36D Gas Fireplace
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent  
Security Secure Vent® 
Selkirk Direct-Temp.
***
Important:  Framing height requires consideration of the hearth 
depth.   Dimension H = H + the thickness of installed hearth.
Please refer to Page 11 (Exterior Vent Terminations) 
for additional guidelines on vent locations.
35
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fir
eplaces