U32S-5 FPI Direct Vent Gas Insert
MAINTENANCE
GENERAL VENT 
MAINTENANCE
Conduct an inspection of the venting system 
semi-annually. Recommended areas to inspect 
as follows:
1)  Check the Venting System for corrosion in 
areas that are exposed to the elements. 
These will appear as rust spots or 
streaks, and in extreme cases, holes. 
These components should be replaced 
immediately.
2)  Remove the Termination Cap, and shine a 
fl ashlight down the Vent. Remove any bird 
nests, or other foreign material.
3)  Check for evidences of excessive 
condensation, such as water droplets forming 
in the inner liner, and subsequently dripping 
out the joints, Continuous condensation can 
cause corrosion of caps, pipe, and fi ttings. 
It may be caused by having excessive 
lateral runs, too many elbows, and exterior 
portions of the system being exposed to 
cold weather.
4)  Inspect joints, to verify that no pipe 
sections or fi ttings have been disturbed, 
and consequently loosened. Also check 
mechanical supports such as Wall Straps, 
or plumbers' tape for rigidity.
GLASS GASKET
 
If the glass gasket requires replacement use 
glass gasket (Part # 936-155).   
Top View of pilot fl ame
Top View of pilot fl ame
Incorrect fl ame pattern will have small, probably 
yellow fl ames, not coming into proper contact 
with the rear of the burner or thermopile. 
DOOR GLASS 
Your FPI  insert is supplied with high temperature, 
5 mm Neoceram ceramic glass that will withstand 
the highest heat that your unit will produce. If 
your glass requires cleaning, we recommend 
using an approved glass cleaner available at 
all authorized dealers. Do not use abrasive 
materials. Do not clean the glass when hot.
In the event that you break your glass by impact, 
purchase your replacement from an authorized 
FPI  dealer only, and follow our step-by-step 
instructions for replacement.
Warning: Do not operate appliance 
with glass panels removed, cracked 
or broken. Replacement of the glass 
should be done by a licensed or 
qualifi ed service person.
Caution: Wear gloves when removing 
damaged or broken glass.
Flush Glass Replacement
Remove the fl ush door front (as per instructions 
in section "Standard Flush Door"). Remove the 
4 glass clips from each corner. Slide in the new 
replacement glass. Push the 4 glass clips back 
onto the frame. 
If you have an incorrect fl ame pattern, contact 