Maintenance
2 7
Travis Industries
4 0 5 1 2 1 6
9 3 5 0 8 0 5 1
Yearly Maintenance (or every two tons) - Continued
Clean the Exhaust Blower (make sure the heater is cool and unplugged)
a
Remove the six screws holding the 
exhaust blower motor in place.
b
11/32" Socket
c
Exhaust 
Motor
Pull the motor out 
(be careful not to 
damage the wiring).
Clean the blower blades, blower 
housing, and exhaust box.
d
Blower 
Blades
Blower 
Housing
Exhaust 
Box
Remove the surround panels 
(see page 11).  Disconnect 
the vent and pull the insert 
forward to gain better access.
Clean the Vent (make sure the heater and vent is cool)
Check the vent sections for creosote 
accumulation (indicating a poorly burning 
stove).  Accumulation over 1/4” must be 
removed.
On vertically vented systems, the dirtiest 
portion is often the point where the vent turns 
upwards (i.e. the "Tee").  Fortunately, the "Tee" 
has a built-in clean out cover.  Remove the 
cover and vacuum out.  While open, use a 
flashlight to look up the pellet vent to check for 
build-up.
Make sure the cap is free of debris 
(especially if it has a screen that could 
become blocked).
Flyash will deposit along 
sections that are horizontal.
AAA
AAA
AA
AA
Warning:
Whenever any portion of the pellet vent is disconnected, the joints must be sealed with
RTV 500° F. silicone sealant.