Genie 37026500123 User Manual

Page of 5
PN# 37026500123       02/26/2010   REV. 1
22
FIG. 6-6
2 x 4 under center of door opening.
CONTACT REVERSE TEST
The force adjustments and limit switch settings
MUST BE COMPLETED before testing.
1. Testing.
• Open garage door using Wall Control.
– Place a 2" x 4" board (laid flat) under center
of garage door opening (FIG. 6-6)
• Close door using Wall Control.
• When door contacts board, the door must stop 
(within 2 seconds) and reverse direction 
returning to open position.
2. Adjustment.
• If the door does not properly reverse.
– Check to see if door has "close" limit 
programmed. It should not have reached its 
"close" limit before hitting board.
– If the door STOPS but does not reverse, 
decrease "CLOSE FORCE" control 
setting slightly (turn it counter-clockwise).
• Test again. Repeat as necessary until door 
reverses upon contacting board. 
CLOSE
1. Press and hold both of the "SET" buttons 
( &  ) together until the green indicator 
light blinks (about 5 seconds). 
2. All close and open travel limit settings are 
erased. Then follow the steps above to 
reprogram close and open travel limits.
NOTE: The opener will not close the door 
automatically unless the Safe-T-Beam
®
System is
installed.
SET
SET
ERASE - OPEN/CLOSE TRAVEL LIMIT
1. By turning the "Close Force Control
clock-
wise, the DOWN force can be increased. By 
turning the "Close Force Control
counter-
clockwise, the DOWN force can be decreased
Set the DOWN force level at the minimum force 
required to close door without reversing.
2. Once the desired level is selected, this stores the 
necessary force level for the DOWN direction in memory.
3. By turning the "Open Force Control"
clockwise
the UP force can be increased. By turning the 
"Open Force Control"
counter-clockwise, the UP
force can be decreased. Set the UP force level at 
the minimum force required to open door without 
stopping.
4. Once the desired level is selected, this stores 
the necessary force level for the UP direction 
in memory.
OPEN
CLOSE
OPEN
CLOSE
UP/DOWN FORCE
OPEN
FORCE
CLOSE
Down Force
Control 
Adjustment
Up Force
Control 
Adjustment
ROTATE
CLOCKWISE
ROTATE
COUNTER-CLOCKWISE
(Increasing Force)
(Decreasing Force)
FIG. 6-5