Genie chainmax 1200 garage door opener User Manual

Page of 27
23
ADJUSTMENT GUIDE 
- FORCE SETTINGS 
FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM
Force settings are pre-programmed at the factory 
and "learned" during the Open/Close Limit settings 
steps.  Some additional Force may be increased.  
For normal use, Force settings should not need 
adjustment with this unit.
However, conditions that might suggest an 
adjustment is necessary are;
Doors with very stiff weather seals.
Doors that start down, then STOP and reverse 
before they close.
Doors that start up, but STOP before they 
completely open.
Force Level
Powerhead LEDs
Round LED
Long LED
Default LED display is the current Force setting
LED indicator colors                                       
 OFF,  
 Blue,  
 Purple,  
 Red
Force Level LED indicator colors
Force Level 1
Blue
ON
 
 
OFF
OFF
Force Level 2
 
 
Blue
ON
Force Level 3
Blue
ON
 
 
Blue
ON
Force Level 4
Purple
ON
 
 
OFF
OFF
Force Level 5
 
 
Purple
ON
Force Level 6
Purple
ON
 
 
Purple
ON
Force Level 7
Red
ON
 
 
OFF
OFF
Force Level 8
 
 
Red
ON
Force Level 9
Red
ON
 
 
Red
ON
 
CAUTION
 
Door closing force is FACTORY set and requires no 
adjustment for normal operation.
s
compensate for a damaged door or a binding 
door track.
s
door spring.
s
described on page 18.
CHANGE FORCE SETTING
Use this guide to ADJUST powerhead FORCE settings.
NOTE: There are nine (9) force levels. 
1. Press 
PROGRAM
SET
 on the powerhead and hold until both 
lights turn steady ON.  Release button.  
Lights go out and Round BLUE light comes ON.
2. Press   three times, Round RED light comes ON. 
3. Press 
PROGRAM
SET
 once to enter the Force Programming 
menu.  The round LED will flash BLUE 3 times, 
then the current Force setting for UP force will 
display on the LEDs.  See table below.
4.  (If current UP Force setting is good, skip to Step 
5.)  Press   to increase or   to decrease UP Force 
settings
 within the available range. 
5. Press 
PROGRAM
SET
 to set UP Force level.  The long LED will 
flash BLUE 3 times, then the current Force setting 
for DOWN force will display on the LEDs.
6.  (If current DOWN Force setting is good, skip to 
Step 7.)  Press   to increase or   to decrease 
DOWN Force settings within the available range. 
7. Press 
PROGRAM
SET
 to set DOWN Force level. Both LEDs flash 
BLUE to confirm.
©2011 
The 
Genie 
Company 
    3/2011