Trek SSDVST-CNM User Manual

Page of 36
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
2
TABLE OF CONTENTS 
Packaging .........................................Page  2
Introduction ......................................Page  2
General Information ..........................Page  2
New York City Approval .....................Page  3
Requirements for the 
   Commonwealth of Massachusetts .Page  4
Safety & Warning Information ..........Page  5
Cold Climate Insulation .....................Page  5
Location ............................................Page  6
Manufactured Home Requirements ..Page  6
Vent Termination Clearances  ............Page  7
Appliance and Vent Clearances .........Page  9
Detailed Installation Steps .................Page  10
Typical Installation Sequence  ...........Page  10
Step 1. Framing .................................Page  10
Step 2. Routing Gas Line ..................Page  10
Fireplace Specifi cations .....................Page  11
Step 3. Install the Vent System .........Page  13
Vent Restrictor Installation ................Page  13
Vertical Termination Systems ............Page  14
Vent Section Length Chart ................Page  14
Vertical Vent Figures and Tables ........Page  17
Horizontal Termination System .........Page  19
Horizontal Vent Figures and Tables ...Page  21
Venting Using Flexible Vent Pipe .......Page  24
Step 4.  Field Wiring .........................Page  25
Step 5.  Optional Blower Kit Wiring ..Page  26
Step 6.  Connecting Gas Line ...........Page  27
Step 7.  Checking Operation .............Page  28
Step 8.  Install logs, Volcanic Stone
 & 
Embers 
 
...........................Page 
28
Step 9.  Installing Glass 
  Enclosure Panels  ............................Page  29
Step 10. Burner Adjustments ............Page  29
Step 11. Hood Installation .................Page  30
Finishing Requirements ....................Page  30
Installation Accessories ....................Page  31
Gas Conversion Kits .................. Page  33
This installation manual will help you obtain a 
safe, effi cient, dependable installation for the 
appliance and vent system. 
Please read and understand these 
instructions before beginning your 
installation.
The  Millivolt appliances have a millivolt gas 
control valve with piezo ignition system which 
provides safe, effi cient operation. If any optional 
accessories that will require electrical power are to 
be installed, the electrical power must be provided 
at the time of appliance installation. 
The  Electronic appliances have an electronic 
intermittent pilot ignition system which provides 
safe, effi cient operation. External electrical power 
is required to operate these appliances. 
PACKAGING
The  assembled vented gas fi replace heater  is 
packaged with:
1 -  One log set located in fi rebox area.
2 -  One plastic bag of glowing embers and a 
plastic bag of volcanic stone located in the 
control compartment.
3  -   One envelope containing the literature pack-
age, located in the fi rebox which consists 
of the homeowner's manual, installation 
instructions, warranty, nailing fl anges (8 
for SSDVST models and 4 for SSDVPF 
models).
4 - One vent restrictor (to be applied as shown 
on Page 13; restrictor is taped to the enve-
lope). 
5 - Hoods (2 for SSDVST models and 3 for 
SSDVPF models), taped to the top of the 
fi replace.
6 - Carton Support (must be removed from the 
control compartment prior to fi rst burn-
ing).
INTRODUCTION 
These vented gas fi replace heaters are sealed 
combustion, air circulating gas fi replaces de-
signed for residential applications. 
Approved Vent Components - These fi replaces 
are designed, tested and listed for operation 
and installation with, the following vent com-
ponents only:
   
Secure Vent™ Direct Vent System Compo-
nents, 
   
Secure Flex™ Flexible Vent Components 
manufactured by Security Chimneys Inter-
national and 
   
Z-FLEX™ Model GA Venting Systems listed 
to UL1777 and ULCS635 manufactured by 
Flexmaster Canada Limited.  
These approved vent system components are 
labeled for identifi cation. DO NOT use any other 
manufacturer’s vent components with these 
appliances.  Use only the correct size venting 
(4-1/2" inner & 7-1/2" outer).
These appliances comply with National Safety 
Standards and are tested and listed by OMNI-
Test Laboratories, Inc.  (Report No. 116-F-32-5) 
to ANSI Z21.88b-2003 (in Canada, CSA-2.33b-
2003), and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas fi replace heaters.
Both millivolt and electronic versions of 
these  appliances are listed by OMNI-Test 
Laboratories for installation in bedrooms 
and Manufactured Homes.
Manufactured Homes - 
See  Manufactured Home Requirements on 
Page 6
 for additional information.
 
       WARNING 
Improper installation, adjust-
ment, alteration, service or 
maintenance can cause injury 
or property damage.  Refer to 
this manual.  For assistance or 
additional information consult 
a qualified installer, service 
agency or the gas supplier.
This appliance is only for use with the type 
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other 
gases, unless a certifi ed kit is used.
Cet appareil doit être utilisé uniquement 
avec les types de gaz indiqués sur la plaque 
signalétique.  Ne pas l'utiliser avec d'autres 
gaz sauf si un kit de conversion certifi é est 
installé.
Misc. Codes / Standards - 
The Installation must conform to local codes or, 
in the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1 / NFPA 54 - latest 
edition, or the Natural Gas and Propane Instal-
lation Code, CSA B149.1 - latest edition.  
The appliance, when installed, must be elec-
trically grounded & wired in accordance with 
local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI / NFPA 
70-latest edition, or the Canadian Electrical 
Code, CSA C22.1 - latest edition.
GENERAL INFORMATION
Note: Installation and repair should be per-
formed by a qualifi ed service person. The 
appliance should be inspected annually by 
a qualifi ed professional service technician. 
More frequent inspections and cleanings may 
be required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative 
that the control compartment, burners and 
circulating air passage ways of the appliance 
be kept clean.
S'assurer que le brùleur et le compartiment des 
commandes sont propres.  Voir les instructions 
d'installation et d'utilisation qui accompagnent 
l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front or back viewing surfaces of the ap-
pliance.
These millivolt and electronic fi replaces are 
designed to operate on natural gas or propane 
gas only. The use of other fuels or combination 
of fuels will degrade the performance of this 
system and may be dangerous.